Description
The product with the part number 191814B-06 falls under the category of PC-based Oscilloscopes/Digitizers. It is identified by the model PCI-5114. This model has a sampling rate of 250 MS/s and an 8-bit resolution, ensuring precise measurements. With a bandwidth of 125 MHz, it can accurately capture a wide range of frequencies. Each channel of the PCI-5114 can utilize up to 256 MB of memory, allowing for extensive data collection and analysis.
Designed in a 3U PCI form factor, it integrates seamlessly into standard computer architectures. The PCI-5114 is built on the National Instruments Synchronization and Memory Core (SMC) architecture, enhancing its performance and reliability. The device offers various onboard memory options, including 8 MB/ch (779745-01), 64 MB/ch (779745-02), and 256 MB/ch (779745-03), catering to different data handling needs.
It features a high-throughput DMA engine that ensures efficient data transfer while keeping CPU usage low. Users can perform self-calibration through software commands, simplifying maintenance and ensuring consistent accuracy. For repetitive signals, the device supports Equivalent-Time Sampling (ETS) at a rate of 5 GS/s, capturing intricate signal nuances.
The PCI-5114 offers a versatile input range, from 40 mVpp to 40 Vpp, and selectable input impedance options of 50 Ω or 1 MΩ, accommodating a wide array of signal types. It excels in capturing triggered waveforms, with the ability to collect more than 1 million waveforms in multiple record mode using hardware trigger rearming.
The maintenance phase start date for this product was December
| Feature | Description |
|---|---|
| Part Number | 191814B-06 |
| Category | PC-based Oscilloscopes/Digitizers |
| Model | PCI-5114 |
| Sampling Rate | 250 MS/s |
| Resolution | 8-bit |
| Bandwidth | 125 MHz |
| Memory Maximum per Channel | 256 MB |
| Form Factor | 3U PCI |
| Architecture | National Instruments Synchronization and Memory Core (SMC) |
| Onboard Memory Options | 8 MB/ch (779745-01), 64 MB/ch (779745-02), 256 MB/ch (779745-03) |
| DMA Engine | High throughput with low CPU usage |
| Calibration | Self-calibration on software command |
| Equivalent-Time Sampling (ETS) | 5 GS/s for repetitive signals |
| Input Range (Selectable) | 40 mVpp to 40 Vpp |
| Input Impedance (Selectable) | 50 Ω or 1 MΩ |
| Triggered Waveforms Capture | More than 1 million in multiple record mode with hardware trigger rearming |
| Maintenance Phase Start Date | December 30, 2022 |
| Availability | Available with Apex Waves |
Question 1: What is the sampling rate of the PCI-5114?
Answer 1: 250 MS/s
Question 2: How much on-board memory can each channel of the PCI-5114 use?
Answer 2: Up to 256 MB
Question 3: What is the bandwidth of the PCI-5114?
Answer 3: 125 MHz
Question 4: What resolution does the PCI-5114 offer?
Answer 4: 8-bit
Question 5: What are the selectable input impedance options for the PCI-5114?
Answer 5: 50 Ω or 1 MΩ