Description
The Part Number 192273A-01 refers to the PXI-5412 model, which falls under the category of PXI Arbitrary Waveform Generators. This particular model is described as a Board Only Kit, NI PXI-5412, 100 MS/s Arb, 14-bit AWG, 32MB, highlighting its key features including the ability to generate arbitrary waveforms at a rate of 100 MS/s (Mega-samples per second) with a 14-bit resolution and a memory capacity of 32MB.
Regarding memory configurations, this model offers three options: 8 MB (779176-01), 32 MB (779176-02), and 256 MB (779176-03), allowing users to choose based on their specific requirements. The Maximum Bandwidth of the PXI-5412 is 20 MHz, with an Update Rate that can reach up to 100 MS/s, ensuring high-performance outputs for a variety of applications.
Software compatibility is broad, including NI-FGEN, LabVIEW, LabWindows/CVI, and Measurement Studio, which provides a versatile development environment. To achieve optimal performance, a Recommended Warm-up Time of 15 minutes is suggested before use. Additionally, it is recommended that the device undergoes calibration At least once every 2 years to maintain accuracy and reliability.
The Operating Temperature Range for the PXI-5412 is from 0 °C to 55 °C, and it has a Storage Temperature Range of -25 °C to 85 °C, allowing it to function in a wide range of environmental conditions. The model has been announced as Mature Status, indicating it is still Available for purchase and repairs by Apex Waves. For calibration needs, there are options for NIST accredited calibrations through a 3rd party; Basic in-house calibration, providing flexibility in maintaining the equipment’s precision.
| Specification | Detail |
|---|---|
| Part Number | 192273A-01 |
| Model | PXI-5412 |
| Category | PXI Arbitrary Waveform Generators |
| Description | Board Only Kit, NI PXI-5412, 100 MS/s Arb, 14-bit AWG, 32MB |
| Memory Configurations | 8 MB (779176-01), 32 MB (779176-02), 256 MB (779176-03) |
| Maximum Bandwidth | 20 MHz |
| Update Rate | Up to 100 MS/s |
| Software Compatibility | NI-FGEN, LabVIEW, LabWindows/CVI, Measurement Studio |
| Recommended Warm-up Time | 15 minutes |
| Calibration Period | At least once every 2 years |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -25 °C to 85 °C |
| Mature Status Announcement | Available for purchase and repairs by Apex Waves |
| Calibration Options | NIST accredited calibrations through a 3rd party; Basic in-house calibration |