The NI 9217 is a C Series Analog Input module with 4 channels, 400 S/s aggregate sample rate, and PT100 RTD compatibility.

In Stock | Ships Today

img

    Description

    The Part Number 779592-01 is associated with the C Series Analog Input, specifically the model NI-9217. This model is described as the NI 9217 4-Ch 100 Ohm RTD 24-bit, 100S/s/ch, Analog Input Module, highlighting its capacity to handle four channels with a significant level of precision and speed.

    With an Aggregate Sample Rate of 400 S/s, this module is designed to efficiently process data across its channels. It supports a Resistance Range from 0 Ω to 400 Ω, ensuring versatility in measuring a wide spectrum of resistive values. Its compatibility with PT100 RTD C and configuration options for both 3- and 4-wire RTD setups further enhance its adaptability for different types of temperature measurements.

    One of the key features of the NI-9217 is its Per channel current excitation capability, which ensures accurate and consistent measurements across all channels. In terms of software, it is compatible with a variety of platforms including NI-DAQmx, LabWindows/CVI, Microsoft Visual C++, and more, offering flexibility in how data can be processed and analyzed.

    The module is built to operate under harsh conditions, with an Operating Temperature Range of -40 °C to 70 °C and a Storage Temperature Range of -40 °C to 85 °C. It also features a robust Operating Humidity Range of 10% RH to 90% RH (non-condensing) and a Storage Humidity Range of 5% RH to 95% RH, ensuring reliability and longevity in a wide range of environmental conditions.

    Specification Detail
    Part Number 779592-01
    Category C Series Analog Input
    Model NI-9217
    Description NI 9217 4-Ch 100 Ohm RTD 24-bit, 100S/s/ch, Analog Input Module
    Channels 4
    Aggregate Sample Rate 400 S/s
    Resistance Range 0 Ω to 400 Ω
    RTD Compatibility PT100 RTD C
    RTD Configuration 3- and 4-wire
    Excitation Per channel current excitation
    Software Compatibility NI-DAQmx, LabWindows/CVI, Microsoft Visual C++, etc.
    Operating Temperature Range -40 °C to 70 °C
    Storage Temperature Range -40 °C to 85 °C
    Operating Humidity Range 10% RH to 90% RH (non-condensing)
    Storage Humidity Range 5% RH to 95% RH

    Question 1: What is the aggregate sample rate of NI-9217?
    Answer 1: 400 S/s

    Question 2: Does NI-9217 support PT100 RTD?
    Answer 2: Yes, it’s compatible with PT100 RTD.

    Question 3: How many channels does NI-9217 have?
    Answer 3: 4 channels

    Question 4: What is the operating temp range of NI-9217?
    Answer 4: -40 °C to 70 °C

    Question 5: Can NI-9217 be used in 3-wire RTD setups?
    Answer 5: Yes, supports 3- and 4-wire RTD setups.