Description
The device comes with an Analog Bandwidth of 300 MHz, ensuring high-frequency signal capture with precision. It boasts a Real-Time Sample Rate of Up to 2 GS/s, allowing for detailed observation of rapidly changing signals. Additionally, the Equivalent Time Sample Rate reaches up to 20 GS/s, providing exceptional resolution for repetitive signals.
For storage and complex data analysis, the device offers versatile Memory Options, including configurations of 8 MB (Part Number: 779772-01), 64 MB (Part Number: 779772-02), and 256 MB (Part Number: 779772-03). This variability supports a range of application needs from basic to advanced data processing and storage requirements.
It is capable of supporting Maximum Channels of Up to 34 phase synchronous 1 GS/s channels in a single PXI chassis, facilitating extensive signal analysis across multiple channels simultaneously. Furthermore, the device’s Sample Rate for Single Channel in Real-Time Interleaved Sampling (TIS) Mode is 2 GS/s, ensuring high-resolution measurements even in demanding applications.
The Maintenance Phase Start Date was initiated on December 30, 2022. This marks the period from which ongoing support and maintenance services are available, ensuring the device’s longevity and reliability in various operational environments.
| Specification | Detail |
|---|---|
| Analog Bandwidth | 300 MHz |
| Real-Time Sample Rate | Up to 2 GS/s |
| Equivalent Time Sample Rate | 20 GS/s |
| Memory Options | 8 MB (Part Number: 779772-01), 64 MB (Part Number: 779772-02), 256 MB (Part Number: 779772-03) |
| Maximum Channels | Up to 34 phase synchronous 1 GS/s channels in a single PXI chassis |
| Sample Rate for Single Channel in Real-Time Interleaved Sampling (TIS) Mode | 2 GS/s |
| Maintenance Phase Start Date | December 30, 2022 |
Question 1: What’s the Analog Bandwidth of the PXI-5152?
Answer 1: The PXI-5152 has a 300 MHz Analog Bandwidth.
Question 2: What is the Real-Time Sample Rate?
Answer 2: Up to 2 GS/s real-time sample rate.
Question 3: How much memory can the PXI-5152 have?
Answer 3: Up to 256 MB, with options for 8 MB, 64 MB, and 256 MB.
Question 4: What’s the Equivalent Time Sample Rate?
Answer 4: Up to 20 GS/s for high resolution on repetitive signals.
Question 5: When did the Maintenance Phase Start?
Answer 5: Began on December 30, 2022, for ongoing support.