Description
The NI PXI-5114 is a high-performance PXI Oscilloscope/Digitizer part number 192897F-03L. This advanced instrument is designed for a wide range of applications requiring high-speed data acquisition and analysis. The PXI-5114 model boasts a 250MS/s sampling rate and a 125 MHz maximum analog bandwidth, making it well-suited for capturing fast transient signals with high fidelity.
The digitizer features 2 input channels with an 8-bit analog input resolution, ensuring accurate signal representation. Users can select an input impedance of either 50 ohms or 1 M ohm, providing flexibility for various signal types. The PXI-5114 supports a wide voltage range from 40 mV to 40 V, accommodating a broad spectrum of signal amplitudes.
Memory options for this device include 8 MB (779466-01), 64 MB (779466-02), and 256 MB (779466-03), with each channel having 256MB of memory, allowing for extensive data storage and retrieval. The device is equipped with multiple triggering options, such as edge, window, hysteresis, and digital, offering versatile triggering capabilities for various measurement scenarios.
The PXI-5114 provides various connector types, including 3 BNC female, 1 SMB jack, and 1 9-pin mini-circular DIN connectors, facilitating easy integration with a wide range of test and measurement setups. The device’s compact dimensions of 8.4 x 0.8 x 5.1 inches and a weight of 16 oz make it highly suitable for space-constrained environments.
In summary, the NI PXI-5114 PXI Oscilloscope/Digitizer is a versatile and powerful instrument designed for high-speed data acquisition and analysis, offering a rich set of features to meet the demanding requirements of various applications
| Specification | Detail |
|---|---|
| Part Number | 192897F-03L |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5114 |
| Description | NI PXI-5114, 250MS/s, 125 MHz, 8-bit, 2-Ch Digitizer w/ 256MB/ Ch |
| Memory Options | 8 MB (779466-01), 64 MB (779466-02), 256 MB (779466-03) |
| Input Channels | 2 |
| Analog Input Resolution | 8 bits |
| Input Impedance | Software selectable 50 or 1 M |
| Voltage Range | 40 mV to 40 V |
| Maximum Analog Bandwidth | 125 MHz |
| Triggering Options | Edge, window, hysteresis, digital |
| Connector Types | 3 BNC female, 1 SMB jack, 1 9-pin mini-circular DIN |
| Weight | 16 oz |
| Dimensions (W x H x D) | 8.4 x 0.8 x 5.1
Question 1: What is the sampling rate of the NI PXI-5114? Question 2: How many input channels does the PXI-5114 have? Question 3: What is the maximum analog bandwidth of the PXI-5114? Question 4: What is the maximum memory per channel for the PXI-5114? Question 5: Which input impedance options does the PXI-5114 offer? |