Description
The USB-6009, with part numbers 779026-01 and 191039D-01L, is a low cost Data Acquisition (DAQ) device manufactured by National Instruments. This device is designed to offer a balance of performance and affordability, making it a suitable choice for various applications that require data acquisition.
It features 8 single-ended or 4 differential analog input channels, allowing for versatile data collection. The analog inputs can be sampled at a rate of up to 48 thousand samples per second (kS/s), ensuring that data is captured accurately and efficiently.
In terms of output capabilities, the USB-6009 provides 2 analog output channels with a 12-bit resolution. The maximum update rate for the analog outputs is 150 Hz, and they can operate within a range of 0 V to +5 V, offering precision in control tasks.
The device also includes 13 digital I/O channels that are compatible with CMOS, LVTTL, and TTL logic levels, enhancing its flexibility in interfacing with various digital devices. Moreover, it features an event counter capable of edge counting with a minimum high/low pulse width of 100 ns, which is useful for measuring frequency or counting events.
Powered directly from the USB bus, the USB-6009 is designed for ease of use and mobility, with a typical power consumption of only 80 mA. It supports the USB 2.0 interface, facilitating easy and quick connections to computers and laptops.
The compact and robust design of the USB-6009, measuring 3.22 x 3.55 x 0.91 inches and weighing just 3 ounces, makes it an ideal choice for portable applications. It can operate within a temperature range of 0 °C to 55 °C, ensuring reliability across various environments, and can be stored within temperatures of -40 °C to 85 °C.
Although declared obsolete by National Instruments, the USB-6009 remains available for purchase and repairs through Apex Waves
| Feature | Specification |
|---|---|
| Part Number | 779026-01, 191039D-01L |
| Category | Low Cost DAQ |
| Model | USB-6009 |
| Manufacturer | National Instruments |
| Analog Input Channels | 8 single-ended or 4 differential |
| Sample Rate | 48 kS/s |
| Analog Output Channels | 2 |
| Analog Output Resolution | 12 bits |
| Analog Output Update Rate | 150 Hz (max) |
| Analog Output Range | 0 V to +5 V |
| Digital I/O Channels | 13 |
| Digital I/O Compatibility | CMOS, LVTTL, TTL |
| Power Source | USB Bus Power |
| Power Consumption | 80 mA (typical) |
| USB Interface | USB 2.0 |
| Event Counter | Edge counting with 100 ns min high/low pulse width |
| Weight | 3 oz |
| Dimensions | 3.22 x 3.55 x 0.91 in |
| Operating Temperature | 0 °C to 55 °C |
| Storage Temperature | -40 °C to 85 °C |
| Obsolete Status | Declared by National Instruments |
| Availability | Available for purchase and repairs by Apex Waves |
Answer 1: Up to 48 kS/s.
Question 2: How many analog inputs does the USB-6009 have?
Answer 2: 8 single-ended or 4 differential.
Question 3: What is the USB-6009’s power source?
Answer 3: Powered via USB.
Question 4: Can the USB-6009 operate with TTL logic levels?
Answer 4: Yes, compatible with CMOS, LVTTL, and TTL.
Question 5: What is the resolution of the USB-6009’s analog outputs?
Answer 5: 12-bit resolution.