Description
The PXI-2576, identified by its part numbers 778572-76 and 193135D-01, falls under the category of PXI Switches and offers a unique set of features and specifications designed for versatile applications. This model is described as a Multi-Bank Multiplexer that includes 16 Banks of 4×1 2-wire Muxes, providing a comprehensive solution for various switching needs.
One of the key features of the PXI-2576 is its topology options, which include parallel measurement configurations and a single multiplexer configuration with 64 2-wire channels. This flexibility allows for efficient and customizable setup based on the specific requirements of the application.
Additionally, the PXI-2576 incorporates a relay counting feature, which is vital for predictive maintenance. This feature counts relay closures for each relay, aiding in the timely identification and resolution of potential issues, thereby ensuring consistent performance and reliability.
When it comes to maintenance, the PXI-2576 supports both basic and detailed recalibration services, ensuring compliance with ISO 9001 audits. This aspect is crucial for maintaining the accuracy and reliability of the device over time.
The relay type used in the PXI-2576 is the single-side stable type, which means it returns to its de-energized state when power is removed. This feature is important for safety and reliability, as it ensures that the device remains in a safe state in the event of a power loss.
| Specification | Detail |
|---|---|
| Part Numbers | 778572-76, 193135D-01 |
| Category | PXI Switches |
| Model | PXI-2576 |
| Description | Multi-Bank Multiplexer (16 Banks of 4×1 2-wire Muxes) |
| Topology Options | Parallel measurement configurations, Single multiplexer with 64 2-wire channels |
| Relay Counting | Counts relay closures for each relay, supports predictive maintenance |
| Recalibration Services | Basic or detailed recalibration, ISO 9001 audit compliance |
| Relay Type | Single-side stable, returns to de-energized state when power is removed |
Question 1: What are the part numbers for PXI-2576?
Answer 1: 778572-76, 193135D-01
Question 2: How many banks does the PXI-2576 have?
Answer 2: 16 banks of 4×1 2-wire Muxes
Question 3: Does the PXI-2576 support predictive maintenance?
Answer 3: Yes, with a relay counting feature.
Question 4: What relay type does the PXI-2576 use?
Answer 4: Single-side stable type
Question 5: Can the PXI-2576 be recalibrated?
Answer 5: Yes, supports basic and detailed recalibration.