Description
The National Instruments PXI-2510 PXI Signal Insertion Switch Module, with part number 193420C-01L (778572-10), is categorized under PXI Switches. This module is specifically designed for electronic reliability tests and hardware-in-the-loop (HIL) applications. It supports a current rating of 2 A and features a 68-Channel configuration for versatile connectivity options.
The PXI-2510 is compatible with the LabVIEW Real-Time Module, enhancing its utility for a wide range of application scenarios. One of its notable specifications is the ability to recognize pulse widths of < 150 ns with digital filtering disabled, making it highly suited for precise measurement and testing tasks. The module utilizes non-latching electromechanical relays, with a typical actuation time of 1 ms, ensuring quick and efficient signal switching.
Regarding durability, the mechanical relay life of the PXI-2510 is rated at 1×108 cycles, while its electrical relay life can reach up to 5×105 cycles at 30 V, 1 A; and 1×105 cycles at 30 V, 2 A, highlighting the module’s reliability and longevity in demanding environments. The front panel connector is a 160 DIN 41612, male, 160 positions, ensuring robust and secure connections. Lastly, this module is designed in a 3U form factor, making it compact and suitable for integration into various PXI systems.
| Specification | Detail |
|---|---|
| Part Number | 193420C-01L (778572-10) |
| Category | PXI Switches |
| Model | PXI-2510 |
| Description | National Instruments PXI-2510 PXI Signal Insertion Switch Module |
| Current Rating | 2 A |
| Channel Count | 68-Channel |
| Application | Electronic reliability tests, Hardware-in-the-loop (HIL) applications |
| Compatible Software | LabVIEW Real-Time Module |
| Pulse Width Recognition (with digital filtering disabled) | < 150 ns |
| Relay Type | Non-latching electromechanical relay |
| Actuation Time (typical) | 1 ms |
| Mechanical Relay Life | 1×108 cycles |
| Electrical Relay Life | 5×105 cycles at 30 V, 1 A; 1×105 cycles at 30 V, 2 A |
| Front Panel Connector | 160 DIN 41612, male, 160 positions |
| Form Factor | 3U