Description
The Part Number 781055-01 refers to a PXI Multifunction DAQ, specifically the model PXIe-6361. This device is part of the X Series DAQ, characterized by its 16 AI (Analog Inputs), 24 DIO (Digital I/O Lines), and 2 AO (Analog Outputs). The Analog Inputs can operate in 16 single-ended or 8 differential configurations, providing versatility in connection and measurement types.
For output capabilities, this model includes 2 channels for Analog Outputs. The Digital I/O capabilities are substantial, with 24 lines available for various digital signal processing tasks. Additionally, the device is equipped with four 32-bit, 100 MHz Counter/Timers, enhancing its utility for precise time-based operations.
When it comes to sampling rates, the PXIe-6361 excels with a Maximum Analog Input Sampling Rate ranging from 1.0 MS/s to 2.0 MS/s, and a Maximum Analog Output Sampling Rate from 2.0 MS/s to 2.86 MS/s. Both Analog Inputs and Outputs have a resolution of 16 bits, ensuring high precision in measurements.
The device utilizes NI-STC3 Timing and Synchronization Technology for advanced time-based operations and synchronization with other devices. Connection to the DAQ is made through a 68-pin female VHDCI connector, providing a reliable and high-density connection interface.
Performance is further supported by a PCI Express Bus Bandwidth capable of reaching up to 250 MB/s, allowing for rapid data transfer and minimal latency. Software support is broad, with compatibility for Windows 10/8/7/Vista/XP, ensuring ease of integration into existing systems.
To maintain optimal performance, a warm-up time of 15 minutes is recommended before use, and calibration is advised at least once every 2 years. The device is relatively lightweight at 7.2 oz and
| Specification | Details |
|---|---|
| Part Number | 781055-01 |
| Category | PXI Multifunction DAQ |
| Model | PXIe-6361 |
| Description | X Series DAQ (16 AI, 24 DIO, 2 AO) |
| Analog Inputs | 16 single-ended or 8 differential |
| Analog Outputs | 2 channels |
| Digital I/O Lines | 24 |
| Counter/Timers | Four 32-bit, 100 MHz |
| Maximum Analog Input Sampling Rate | 1.0 MS/s to 2.0 MS/s |
| Maximum Analog Output Sampling Rate | 2.0 MS/s to 2.86 MS/s |
| Resolution | 16 bits for both AI and AO |
| Timing and Synchronization Technology | NI-STC3 |
| Connector Type | 68-pin female VHDCI |
| PCI Express Bus Bandwidth | Up to 250 MB/s |
| Software Support | Windows 10/8/7/Vista/XP |
| Warm-up Time | 15 minutes |
| Calibration Period | At least once every 2 years |
| Weight | 7.2 oz |
| Operating Temperature Range | 0 to 55 °C |
| Storage Temperature Range | -40 to 70 º
Question 1: What is the part number for the PXIe-6361? Question 2: How many analog inputs does the PXIe-6361 have? Question 3: What is the max AO sampling rate for the PXIe-6361? Question 4: What type of connector does the PXIe-6361 use? Question 5: How often should the PXIe-6361 be calibrated? |