Description
The National Instruments PXI-2512 Signal Insertion Switch Module, with the part number 193475A-02L and NI part number 778572-12, falls under the category of PXI Switches. This module is designed to facilitate efficient signal routing within a PXI system, providing a robust solution for various test and measurement applications.
The PXI-2512 boasts a configuration of 7 channels, enabling versatile connection setups for multiple signal paths. This model is specifically engineered to handle a maximum switching voltage of 50 VDC and 30 V ACrms, with a maximum switching current of 10 A. Additionally, it can support a maximum pulse current of 50 A for up to 600 μs, highlighting its capability to manage significant power levels for brief durations.
Regarding its operational characteristics, the PXI-2512 features a current detection limit of 10.5 A typical, complemented by a current detection delay of 20 ms. These specifications ensure timely and accurate monitoring of current flow through the module, enhancing safety and reliability during testing procedures.
Connectivity is facilitated through two DSUB, 8 position male front panel connectors, and the unit comes with cable accessories including one DB8F-40A Cable (8-pin DSUB) and one DB8F-40A Cable (to bare wire), ensuring easy integration into a variety of setups. The module’s power consumption is optimized, requiring only 1.0 Watts at 3.3V and 13.0 Watts at 5V, making it an energy-efficient choice for continuous operation.
Physically, the PXI-2512 presents as a 3U, two slot, PXI module, weighing 403 g (14.2 oz) with dimensions of 21.6 cm × 4.1 cm &
| Specification | Details |
|---|---|
| Part Number | 193475A-02L |
| Category | PXI Switches |
| Model | PXI-2512 |
| Description | National Instruments PXI-2512 Signal Insertion Switch Module |
| NI Part Number | 778572-12 |
| Channels | 7-Channel |
| Current Detection Limit | 10.5 A typical |
| Current Detection Delay | 20 ms |
| Front Panel Connectors | Two DSUB, 8 position male |
| Cable Accessories | One DB8F-40A Cable (8-pin DSUB), One DB8F-40A Cable (to bare wire) |
| Maximum Switching Voltage | 50 VDC, 30 V ACrms |
| Maximum Switching Current | 10 A |
| Maximum Pulse Current | 50 A (for 600 μs max) |
| Power Consumption | 1.0 Watts at 3.3V, 13.0 Watts at 5V |
| Physical Size | 3U, two slot, PXI module |
| Weight | 403 g (14.2 oz) |
| Dimensions | 21.6 cm × 4.1 cm × 13.0 cm |
| Maintenance Phase Start Date | June 30, 2023 |
Question 1: What is the part number for the PXI-2512?
Answer 1: 193475A-02L
Question 2: How many channels does the PXI-2512 have?
Answer 2: 7 channels
Question 3: What is the max switching voltage of the PXI-2512?
Answer 3: 50 VDC
Question 4: What is the typical current detection limit for PXI-2512?
Answer 4: 10.5 A
Question 5: What connectors come with the PXI-2512?
Answer 5: Two DSUB, 8 position male front