The PXI Multifunction DAQ, model PXI-6255, has a listed part number of 193618A-01, with the correct part number being 779547-01. This device is equipped with 80 analog inputs, 24 digital I/O, and 2 analog outputs, providing a comprehensive solution for data acquisition needs.
The input resolution of this device is 16 bits, ensuring precise measurement and data accuracy. It is compatible with NI SCC and SCXI platforms, offering flexibility in system integration. The PXI-6255 also supports IEEE 1451.4 TEDS sensors, enhancing its capability to work with smart sensors for automated configuration and data collection.
Software compatibility includes NI LabVIEW SignalExpress, allowing for easy integration with existing software environments for data analysis and processing. The device features 2 68-pin VHDCI I/O connectors, providing robust and reliable connections for various signal types.
The recommended warm-up time for optimal performance is 15 minutes, and it is advised to calibrate the device at least once in 2 years to maintain accuracy. Weighing at 8.3 oz, it is designed for easy installation in various setups.
The operating temperature range is from 0 °C to 55 °C, with a storage temperature range of -20 °C to 70 °C. It can operate within a humidity range of 10% RH to 90% RH (non-condensing), ensuring reliable performance in diverse environmental conditions. The vibration tolerance is 0.3 grms (5 to 500 Hz) when operating and 2.4 grms (5 to 500 Hz) in non-operating conditions, indicating robustness against mechanical disturbances.
Despite its obsolete status as announced by National Instruments, the PXI-6255 is available at Apex Waves, offering a valuable option for systems requiring a high-performance data acquisition solution.
| Specification | Detail |
|---|---|
| Part Number | 193618A-01 (Listed), 779547-01 (Correct) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6255 |
| Analog Inputs | 80 |
| Digital I/O | 24 |
| Analog Outputs | 2 |
| Input Resolution | 16 bits |
| Compatible Platforms | NI SCC and SCXI |
| Compliance | IEEE 1451.4 TEDS sensors |
| Software Compatibility | NI LabVIEW SignalExpress |
| I/O Connectors | 2 68-pin VHDCI |
| Recommended Warm-up Time | 15 minutes |
| Calibration Interval | At least once in 2 years |
| Weight | 8.3 oz |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -20 °C to 70 °C |
| Humidity Range | 10% RH to 90% RH (non-condensing) |
| Vibration (Operating) | 0.3 grms (5 to 500 Hz) |
| Vibration (Non-operating) | 2.4 grms (5 to 500 Hz) |
| Obsolete Status | Announced by National Instruments, available at Apex Waves |