img

193718C-02L

The PXI-5600 is an RF downconverter with a 20 MHz bandwidth, operating from 9 kHz to 2.7 GHz, and features exceptional phase noise and dynamic range.

In Stock | Ships Today

img

    Description

    The 778283-01 is a cutting-edge RF Downconverter, specifically the PXI-5600 model, designed to meet the demanding requirements of modern RF signal processing. This powerful device offers a real-time bandwidth of 20 MHz, ensuring efficient signal analysis and processing across a broad spectrum. With an operating frequency range spanning from 9 kHz to 2.7 GHz, it covers a wide array of applications, from basic research to advanced telecommunications.

    It boasts an average noise density of < -140 dBm/Hz, ensuring superior signal clarity and detection capability. The spurious-free dynamic range of > 80 dB and phase noise of < -94 dBc/Hz at 10 kHz offset further enhance its performance, enabling accurate and reliable measurements even in challenging signal environments.

    The PXI-5600’s timebase stability is rated at ±20 ppb, with a timebase accuracy of ±50 ppb, ensuring precise timing and synchronization for high-precision applications. Its measurement repeatability is exceptional, with a variance of < 0.2 dB for -30 dBm input at 1 MHz bandwidth, highlighting the device’s reliability and consistency.

    Compatibility with software is broad, requiring NI-RFSA 2.1, NIPXI-5600 Support, and an ADE such as LabVIEW, LabWindows/CVI, or Microsoft C/C++, offering flexibility in programming and integration into existing systems. The device features multiple connectors, including FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, and INPUT, providing versatile connection options for various setups.

    Specification Details Part Number 778283-01 Category RF Downconverters Model PXI-5600 Real-time Bandwidth 20 MHz Operating Frequency Range 9 kHz to 2.7 GHz Average Noise Density < -140 dBm/Hz Spurious-free Dynamic Range > 80 dB Phase Noise < -94 dBc/Hz at 10 kHz offset Timebase Stability ±20 ppb Timebase Accuracy ±50 ppb Measurement Repeatability < 0.2 dB for -30 dBm input at 1 MHz bandwidth Software Requirements NI-RFSA 2.1, NIPXI-5600 Support, ADE such as LabVIEW, LabWindows/CVI, Microsoft C/C++ Connectors FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT Recommended Warm-up Time 20 minutes

    Question 1: What is the real-time bandwidth of the PXI-5600?
    Answer 1: 20 MHz

    Question 2: What frequency range does the PXI-5600 cover?
    Answer 2: 9 kHz to 2.7 GHz

    Question 3: What is the average noise density of PXI-5600?
    Answer 3: < -140 dBm/Hz Question 4: What software is required for the PXI-5600 operation?
    Answer 4: NI-RFSA 2.1, NIPXI-5600 Support

    Question 5: What is the phase noise of the PXI-5600 at 10 kHz offset?
    Answer 5: < -94 dBc/Hz