Description
The product comes with a variety of Part Numbers including 780114-01, 780114-04, and 779628-01, ensuring compatibility and options for different requirements.
Featuring a high Resolution of 16-bit, it provides precise and accurate data representation. The device supports multiple Triggering Types, including both Analog Triggering and Digital Triggering, allowing for flexible signal processing.
It is equipped with Two 32-bit, 80 MHz Counters/Timers, enhancing its timing and counting capabilities. The Analog Input Channels can be configured as 32 single-ended or 16 differential channels, offering versatility in connection setups.
With a Maximum Sample Rate of 1.25 MS/s per channel, it ensures high-speed data acquisition. The device also features 4 Analog Output Channels for comprehensive output options.
It supports Four High-Speed Data Streams for efficient Signal Streaming, ensuring swift data transfer. Utilizing NI-MCal Calibration Technology, it offers reliable and precise calibration.
This product is compatible with several Supported Operating Systems, including Windows Vista, Windows XP, and Windows 2000, providing flexibility in system integration.
The Recommended Warm-Up Time is 30 minutes, ensuring the device is ready for optimal performance. It requires Calibration Frequency of at least once every 2 years to maintain accuracy.
For connectivity, it features an Interface of USB 2.0 Hi-Speed or full-speed, offering easy and fast connections.
The Physical Dimensions (Screw Terminal) are 10.5 x 6.73 x 1.75 in., and for the BNC Model, it measures
| Specification | Detail |
|---|---|
| Part Numbers | 780114-01, 780114-04, 779628-01 |
| Resolution | 16-bit |
| Triggering Types | Analog Triggering, Digital Triggering |
| Counters/Timers | Two 32-bit, 80 MHz |
| Analog Input Channels | 32 single-ended or 16 differential |
| Maximum Sample Rate | 1.25 MS/s per channel |
| Analog Output Channels | 4 |
| Signal Streaming | Four High-Speed Data Streams |
| Calibration Technology | NI-MCal |
| Supported Operating Systems | Windows Vista, Windows XP, Windows 2000 |
| Recommended Warm-Up Time | 30 minutes |
| Calibration Frequency | At least once every 2 years |
| Interface | USB 2.0 Hi-Speed or full-speed |
| Physical Dimensions (Screw Terminal) | 10.5 x 6.73 x 1.75 in. |
| Physical Dimensions (BNC Model) | 11.25 x
Question 1: What is the resolution of the USB-6259? Question 2: How many analog input channels does it have? Question 3: What is the USB-6259’s max sample rate per channel? Question 4: What operating systems is the USB-6259 compatible with? Question 5: What is the recommended calibration frequency? |