Description
The product with the part number 779778-01 falls under the category of PXI Multifunction DAQ and is identified by the model PXIe-6259. It is designed to cater to a wide range of data acquisition and measurement needs.
This device is equipped with 32 analog inputs, allowing for extensive data collection from multiple sources simultaneously. Additionally, it features 48 digital I/O lines, providing ample capacity for digital input/output operations. For outputs, it offers 4 analog outputs, enabling the device to output data or signals based on the analysis or processing done.
When it comes to sampling rates, the PXIe-6259 excels with a maximum sample rate of 1.25 MS/s and a maximum update rate of 2.86 MS/s, ensuring high-speed data capture and signal generation. The input/output coupling is designed with DC, catering to a variety of signal types.
This device supports the Earliest NI-DAQmx Version Supported as NI-DAQmx 8.3, indicating compatibility with specific software versions for optimal operation. The analog input ground-reference settings are versatile, offering non-referenced single-ended mode, referenced single-ended mode, and differential mode, allowing for flexible configuration based on the measurement requirements.
The obsolete status of this product has been announced, indicating that it may no longer be in production or readily available in the near future. However, it is still available for purchase and repairs by Apex Waves, ensuring support and availability for current and new users.
| Specification | Detail |
|---|---|
| Part Number | 779778-01 |
| Category | PXI Multifunction DAQ |
| Model | PXIe-6259 |
| Analog Inputs | 32 |
| Digital I/O Lines | 48 |
| Analog Outputs | 4 |
| Maximum Sample Rate | 1.25 MS/s |
| Maximum Update Rate | 2.86 MS/s |
| Input/Output Coupling | DC |
| Earliest NI-DAQmx Version Supported | NI-DAQmx 8.3 |
| Analog Input Ground-Reference Settings | Non-referenced single-ended mode, Referenced single-ended mode, Differential mode |
| Obsolete Status | Announced |
| Availability | Available for purchase and repairs by Apex Waves |
Question 1: What’s the max sample rate of the PXIe-6259?
Answer 1: 1.25 MS/s
Question 2: How many digital I/O lines does the PXIe-6259 have?
Answer 2: 48
Question 3: Is the PXIe-6259 considered obsolete?
Answer 3: Yes, but still available at Apex Waves.
Question 4: What is the earliest NI-DAQmx version supported by PXIe-6259?
Answer 4: NI-DAQmx 8.3
Question 5: How many analog outputs does PXIe-6259 provide?
Answer 5: 4