img

196150C-03L

The National Instruments PXI-4495 is a PXI Sound and Vibration Module designed for high-channel-count applications, featuring built-in filters and IEPE support.

In Stock | Ships Today

img

    Description

    The National Instruments PXI-4495 is a high-performance PXI Sound and Vibration Module, designed to meet the demands of high-channel-count sound and vibration applications. With its part number 196150C-03L, which can be specified as either the standard module (780059-01) or with software (780060-01), this device falls under the category of PXI DSA.

    The PXI-4495 model is renowned for its comprehensive approach to sound and vibration measurement and analysis. It is specifically engineered for applications requiring meticulous sound and vibration data acquisition, making it an ideal solution for a wide range of industrial and research environments.

    This module excels in capturing data from 24-bit simple sources and is compatible with IEPE constant current signal modules, enhancing its versatility in various testing scenarios. One of the standout features of the PXI-4495 is its capability for synchronous sampling on all channels, ensuring precise timing and correlation in data collection across multiple inputs.

    To maintain data integrity and reduce signal noise, the module is equipped with built-in antialiasing filters. These filters automatically adjust to the sampling rate, thereby optimizing performance and ensuring clean signal acquisition. Furthermore, the module offers programmable gain up to 20 dB, selectable in 10 dB steps from 0 to +30 dB, allowing users to fine-tune the input signal strength for optimal resolution.

    The PXI-4495 supports NI-DAQmx driver software, providing a powerful and flexible interface for data acquisition, signal processing, and analysis. However, it is important to note that it is not compatible with Traditional NI-DAQ (Legacy) software, which may affect compatibility with certain legacy systems.

    Among its advanced features, the module boasts the ability to read and write to TEDS Class 1 smart sensors and offers IEPE support. This functionality enhances the flexibility and applicability of the PXI-4495 in sophisticated measurement setups, allowing for seamless integration with a wide range of sensors and transducers.

    Specification Detail
    Part Number 196150C-03L (Standard Module: 780059-01, With Software: 780060-01)
    Category PXI DSA
    Model PXI-4495
    Description National Instruments PXI-4495 PXI Sound and Vibration Module
    Applications High-channel-count sound and vibration applications
    Input Type 24-bit simple sources, IEPE constant current signal module
    Sampling Synchronous sampling on all channels
    Filters Built-in antialiasing filters, automatically adjustable to the sampling rate
    Gain Programmable, up to 20 dB, selectable in 10 dB steps from 0 to +30 dB
    Driver Software NI-DAQmx, not compatible with Traditional NI-DAQ (Legacy)
    Features Ability to read and write to TEDS Class 1 smart sensors, IEPE support

    Question 1: What is the part number of the PXI-4495?
    Answer 1: 196150C-03L

    Question 2: Does the PXI-4495 support IEPE modules?
    Answer 2: Yes, it supports IEPE constant current signal modules.

    Question 3: Can the PXI-4495 do synchronous sampling?
    Answer 3: Yes, it supports synchronous sampling on all channels.

    Question 4: What software is compatible with PXI-4495?
    Answer 4: NI-DAQmx driver software

    Question 5: Does PXI-4495 have built-in filters?
    Answer 5: Yes, it has built-in antialiasing filters.