The Part Number for this device is 196368B-01 (780166-01), and it falls under the Category of PXI Oscilloscopes/Digitizers. The model being discussed is the PXI-5900, which is a PXI Differential Amplifier.
This device features 2 Input Channels with options for GND, AC, and DC input coupling, providing flexibility for various signal measurements. The Input Impedance is 50 Ω ±2%, and it is software-selectable, allowing for precise adjustments as needed for specific applications. For connectivity, it uses BNC input and SMB output connectors.
The Vertical Gain Accuracy of this amplifier stands at 0.25 ±0.2%, ensuring high precision in signal amplification. It exhibits a Zero Input Offset Error of 500 μV, maintaining accuracy in signal processing. The Passband Flatness is within 1 dB, which helps in maintaining signal integrity across the bandwidth. Its Common-Mode Rejection Ratio is impressive at 70 dB at 60 Hz, significantly reducing noise in signal measurements.
With a Slew Rate of 100 V/μs (balanced differential input), the PXI-5900 is capable of handling rapid changes in input signal. It is compatible with NI-SCOPE 3.5.1 and NI Measurement & Automation Explorer (MAX) software, providing a versatile and user-friendly interface for data acquisition and analysis.
The device is lightweight, weighing only 173 grams, and has a Form Factor of a 3U, one slot PXI module, making it compact and easy to integrate into PXI systems. Its Dimensions are 21.6 cm × 2.0 cm × 13.0 cm, further emphasizing its compactness.
Regarding voltage handling capabilities, it has a Differential Input Voltage Range of ±20 V (40 Vpk-pk
| Specification | Details |
|---|---|
| Part Number | 196368B-01 (780166-01) |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5900 |
| Type | PXI Differential Amplifier |
| Input Channels | 2 with GND, AC, and DC input coupling |
| Input Impedance | 50 Ω ±2%, software-selectable |
| Connectors | BNC input, SMB output |
| Vertical Gain Accuracy | 0.25 ±0.2% |
| Zero Input Offset Error | 500 μV |
| Passband Flatness | 1 dB |
| Common-Mode Rejection Ratio | 70 dB at 60 Hz |
| Slew Rate | 100 V/μs (balanced differential input) |
| Compatible Software | NI-SCOPE 3.5.1, NI Measurement & Automation Explorer (MAX) |
| Weight | 173 grams |
| Form Factor | 3U, one slot PXI module |
| Dimensions | 21.6 cm × 2.0 cm × 13.0 cm |
| Differential Input Voltage Range | ±20 V (40 Vpk-pk) |
| Single-Ended Output Voltage | ±5 V (10 Vpk-pk) |
| Common-Mode Input Voltage Range | ±10 V |