img

196429A-01L

The NI PXI-2510 is a 68-Channel 2A FIU Switch Module ideal for electronic reliability tests and HIL applications.

In Stock | Ships Today

img

    Description

    >

    The product with the part number 778572-10 falls under the category of PXI Switches. It is specifically the PXI-2510 model. This unit is described as the NI PXI-2510 68-Channel 2A FIU Switch Module, which is designed to handle a significant number of channels, precisely 68, with a current rating of 2 A.

    Its primary function is to serve as a Signal Insertion Switch Module/Fault Insertion Unit (FIU), making it a critical component in setups that require precise signal manipulation and fault insertion capabilities. The PXI-2510 is particularly suited for applications involving electronic reliability tests and hardware-in-the-loop (HIL) simulations, where its ability to manage complex signal routing and fault simulation scenarios is invaluable.

    One of the notable features of this module is its ability to recognize pulse widths as small as <150 ns when digital filtering is disabled, allowing for the handling of very fast signals. The typical relay actuation time is around 1 ms, ensuring prompt signal switching. Additionally, the module boasts a mechanical relay life of 1×108 cycles, and an electrical relay life that varies depending on the load – 5×105 cycles at 30 V, 1 A, and 1×105 cycles at 30 V, 2 A, highlighting its durability and reliability for long-term use.

    Connectivity is facilitated through a 160 DIN 41612, male (160 positions) connector on the front panel, ensuring compatibility with a wide range of test and measurement setups. This makes the PXI-2510 a versatile and essential tool for engineers and technicians working in various fields of electronic testing and simulation.

    Specification Detail
    Part Number 778572-10
    Category PXI Switches
    Model PXI-2510
    Description NI PXI-2510 68-Channel 2A FIU Switch Module
    Channels 68
    Current Rating 2 A
    Function Signal Insertion Switch Module/Fault Insertion Unit (FIU)
    Applications Electronic reliability tests, Hardware-in-the-loop (HIL)
    Minimum Pulse Width Recognition <150 ns (with digital filtering disabled)
    Relay Actuation Time (typical) 1 ms
    Mechanical Relay Life 1×108 cycles
    Electrical Relay Life at 30 V, 1 A 5×105 cycles
    Electrical Relay Life at 30 V, 2 A 1×105 cycles
    Front Panel Connector 160 DIN 41612, male (160 positions)
    Question 1: What is the current rating of the PXI-2510?
    Answer 1: The PXI-2510 has a 2A current rating.

    Question 2: How many channels does the PXI-2510 support?
    Answer 2: It supports 68 channels.

    Question 3: What type of connector does PXI-2510 use?
    Answer 3: Uses a 160 DIN 41612, male connector.

    Question 4: What is the relay actuation time of PXI-2510?
    Answer 4: Approximately 1 ms.

    Question 5: What’s the mechanical relay life of PXI-2510?
    Answer 5: 1×10^8 cycles.