Description
The PXI Chassis, specifically model PXI-1036, is identified by its part numbers 196972D-01L and 779382-01. This chassis is designed as a backplane that supports a 6 Slot Chassis configuration, providing flexibility and scalability for various testing and measurement applications.
It is compatible with either a remote controller or a 2-space embedded controller, ensuring versatility in how it can be integrated into different system architectures. With a maximum system bandwidth of 132 MB/s, it ensures quick data transfers and efficient operation across all connected devices.
Each slot within the PXI-1036 has a cooling capacity of 30 W, which is critical for maintaining optimal performance and preventing overheating of components. Additionally, the chassis features a Star Trigger Slot located in Slot 2, enabling precise synchronization between modules.
Operating flexibility is further enhanced by its AC input voltage range of 100 to 240 VAC, along with an input frequency of 50/60 Hz and an input current rating of 4-2 A. The chassis supports 8 PXI trigger lines, facilitating complex signal routing and triggering configurations.
The configuration of this chassis can be efficiently managed using the Measurement & Automation Explorer (MAX) tool, simplifying setup and adjustments. Weighing in at 11 lbs., and with dimensions of 6.97 x 10.12 x 8.38 in., the PXI-1036 offers a compact and lightweight solution without compromising on functionality or performance.
This model is classified as mature, indicating that it has reached a stable phase in its lifecycle. However, it remains available for purchase and repairs through Apex Waves, ensuring long-term support for users who rely on this essential component in their PXI systems.
| Specification | Detail |
|---|---|
| Part Number | 196972D-01L, 779382-01 |
| Category | PXI Chassis |
| Model | PXI-1036 |
| Description | Backplane, PXI-1036, 6 Slot Chassis |
| Compatible Controllers | Remote controller or 2-space embedded controller |
| Maximum System Bandwidth | 132 MB/s |
| Slot Cooling Capacity | 30 W |
| Star Trigger Slot | Slot 2 |
| AC Input Voltage Range | 100 to 240 VAC |
| Input Frequency | 50/60 Hz |
| Input Current Rating | 4-2 A |
| PXI Trigger Lines | 8 |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Weight | 11 lbs. |
| Dimensions | 6.97 x 10.12 x 8.38 in. |
| Status | Mature, available for purchase and repairs by Apex Waves |