Description
The device is available with Part Numbers 779647-30 and 779647-31, designed in a Single Slot, 3U PXI Module form factor for easy integration into PXI systems. It features a versatile Output Voltage (SMU Channel) of ± 20 V (Four-Quadrant), providing flexibility for a wide range of testing and measurement scenarios.
The Power Output (SMU Channel) can deliver up to 40 W in quadrants I and III, and up to 10 W in quadrants II and IV, making it suitable for a variety of load conditions. Its Current Measurement Resolution goes down to 1 nA, allowing for precise current measurements even at very low levels.
Additionally, the module includes a Utility Channel Output capable of supplying up to 6 V and 1 A, with a Utility Channel Resolution of 16-bit, ensuring fine control over voltage and current outputs. Users can select between Constant Voltage or Constant Current source modes for flexible operation depending on the requirements of the task at hand. The availability of Remote Sense on the SMU Channel enhances measurement accuracy by compensating for voltage drops in the test leads.
When it comes to software, the module is compatible with NI-DCPower, LabVIEW, and LabWindows/CVI, offering a broad range of programming environments to suit different user preferences and application needs. The Warm-up Time for the module is approximately 30 minutes, and a Calibration Period is recommended annually or every two years to maintain accuracy and performance.
The device weighs in at 11 oz and has compact Dimensions of 8.5 x 5.1 x 0.8 inches, making it a lightweight and space-efficient option for integrating into PXI chassis. Its Operating Temperature Range ensures reliable performance across a variety of environmental conditions, further enhancing its versatility and applicability in different settings.
| Specification | Detail |
|---|---|
| Part Numbers | 779647-30, 779647-31 |
| Form Factor | Single Slot, 3U PXI Module |
| Output Voltage (SMU Channel) | ± 20 V (Four-Quadrant) |
| Power Output (SMU Channel) | Up to 40 W in quadrants I and III, Up to 10 W in quadrants II and IV |
| Current Measurement Resolution | Down to 1 nA |
| Utility Channel Output | Up to 6 V and 1 A |
| Utility Channel Resolution | 16-bit |
| Source Modes | Constant Voltage or Constant Current |
| Remote Sense | Available on SMU Channel |
| Software Compatibility | NI-DCPower, LabVIEW, LabWindows/CVI |
| Warm-up Time | 30 minutes |
| Calibration Period | Recommended Annually or Every Two Years |
| Weight | 11 oz |
| Dimensions | 8.5 x 5.1 x 0.8 in |
| Operating Temperature Range
Question 1: What are the part numbers for the PXI-4130? Question 2: What output voltage does the PXI-4130 support? Question 3: How much power can the PXI-4130 deliver in quadrant I and III? Question 4: What is the current measurement resolution of the PXI-4130? Question 5: What software is compatible with the PXI-4130? |