Description
The part number for this device is 197180B-01L, with alternative part numbers being 779647-30 and 779647-31. It falls under the category of PXI Source Measure Units and is identified as model PXI-4130. This device is designed as a Single Slot, 3U PXI Module, ensuring a compact and efficient form factor for integration into PXI systems.
It is capable of delivering an output voltage of ± 20 V, with the ability to source up to 40 W of power in Quadrants I and III and sink up to 10 W of power in Quadrants II and IV. The device boasts a high level of precision, with a current measurement resolution that goes down to 1 nA, and a utility channel output that can provide up to 6 V and 1 A.
The set-point and measurement resolution of this unit is 16-bit, offering high accuracy for various measurements and settings. It is compatible with several software platforms, including NI-DCPower, LabVIEW, and LabWindows/CVI, ensuring flexibility and ease of integration into different systems. The warm-up time is approximately 30 minutes, and it requires calibration either annually or every two years to maintain accuracy and performance.
The physical dimensions of the PXI-4130 are 8.5 x 5.1 x 0.8 inches, and it weighs about 11 oz. This device is designed to operate within a temperature range of 0 °C to 55 °C and can be stored in temperatures ranging from -40 °C to 70 °C. The humidity range for both operating and storage conditions is 10% to 90% and 5% to 95%, respectively, ensuring the device’s durability and reliability in various
| Feature | Description |
|---|---|
| Part Number | 197180B-01L |
| Alternative Part Numbers | 779647-30, 779647-31 |
| Category | PXI Source Measure Units |
| Model | PXI-4130 |
| Form Factor | Single Slot, 3U PXI Module |
| Output Voltage | ± 20 V |
| Sourcing Power (Quadrants I and III) | Up to 40 W |
| Sinking Power (Quadrants II and IV) | Up to 10 W |
| Current Measurement Resolution | Down to 1 nA |
| Utility Channel Output | Up to 6 V and 1 A |
| Set-point and Measurement Resolution | 16-bit |
| Software Compatibility | NI-DCPower, LabVIEW, LabWindows/CVI |
| Warm-up Time | 30 minutes |
| Calibration Period | Annually or Every Two Years |
| Physical Dimensions | 8.5 x 5.1 x 0.8 in |
| Weight | 11 oz |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -40 °C to 70 °C |
| Humidity Range (Operating and Storage) | 10% to 90%, 5% to 95%
Question 1: What is the output voltage of PXI-4130? Question 2: How much power can PXI-4130 source and sink? Question 3: What is the current measurement resolution of PXI-4130? Question 4: What software is PXI-4130 compatible with? Question 5: What is PXI-4130’s warm-up time and calibration frequency? |