Description
“`html
The product with part numbers 779647-30 and 779647-31 is a high-performance, single-slot, 3U PXI module designed for a wide range of applications. This module offers an output range of ± 20 V, ensuring versatile use across various testing scenarios.
It features an impressive sourcing capability of up to 40 W in Quadrants I and III, and a sinking capability of up to 10 W in Quadrants II and IV. This ensures that the module can handle a variety of loads efficiently. The current measurement resolution goes down to 1 nA, allowing for highly precise current measurements.
The module also includes a utility channel output capable of delivering up to 6 V and 1 A, which adds to its versatility. With a 16-bit set-point and measurement resolution, it guarantees high accuracy in settings and readings. It is compatible with NI-DCPower, LabVIEW, and LabWindows/CVI software, making it a flexible choice for many software environments.
To achieve optimal performance, a recommended warm-up time of 30 minutes is suggested. The module should undergo calibration either annually or every two years, depending on use, to maintain its precision. Weighing in at just 11 oz and with dimensions of 8.5 x 5.1 x 0.8 in, this module is both lightweight and compact, making it easy to integrate into existing setups.
It operates within a temperature range of 0 °C to 55 °C, ensuring reliability across a wide range of environmental conditions. The storage temperature range extends further, from -40 °C to 71 °C, offering flexibility in storing the module when not in use. This module represents a blend of performance, precision, and versatility, designed to meet the demands of modern testing and measurement applications.
“`
| Specification | Detail |
|---|---|
| Part Numbers | 779647-30, 779647-31 |
| Form Factor | Single-slot, 3U PXI module |
| Output Range | ± 20 V |
| Sourcing Capability (Quadrants I and III) | Up to 40 W |
| Sinking Capability (Quadrants II and IV) | Up to 10 W |
| Current Measurement Resolution | Down to 1 nA |
| Utility Channel Output | Up to 6 V and 1 A |
| Set-point and Measurement Resolution | 16-bit |
| Software Compatibility | NI-DCPower, LabVIEW, LabWindows/CVI |
| Recommended Warm-up Time | 30 minutes |
| Calibration Period | Annually or every two years |
| Weight | 11 oz |
| Dimensions | 8.5 x 5.1 x 0.8 in |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | Question 1: What is the output voltage range of the PXI-4130? Answer 1: ±20 V Question 2: What is the PXI-4130’s maximum sourcing capability? Question 3: How precise is the PXI-4130’s current measurement resolution? Question 4: What software is the PXI-4130 compatible with? Question 5: What are the recommended calibration intervals for the PXI-4130? |