The PXI-4130 model is a robust and versatile single slot, 3U PXI module designed for a variety of applications. It comes with part numbers 779647-30, 779647-31, allowing for easy identification and ordering.
This module stands out for its impressive output range of ±20 V, ensuring it can handle a wide range of tasks. Additionally, it boasts a power output capability of up to 40 W in quadrants I and III, and up to 10 W in quadrants II and IV, making it suitable for various power requirements.
One of the PXI-4130’s key features is its current measurement resolution, which goes down to 1 nA. This high resolution allows for extremely precise measurements, essential for many testing and development environments. Furthermore, it features a utility channel output of up to 6 V and 1 A, adding to its versatility.
Compatibility with programming software such as NI-DCPower, LabVIEW, and LabWindows/CVI is another significant advantage, offering a range of options for programming and integration into existing systems.
The device requires a warm-up time of 30 minutes before reaching optimal performance. It is recommended to undergo calibration annually or every two years to maintain accuracy and reliability.
Despite its powerful features, the PXI-4130 is lightweight, weighing just 11 oz, and has compact dimensions of 8.5 x 5.1 x 0.8 inches, making it easy to integrate into any setup. It operates within a temperature range of 0 °C to 55 °C and can be stored in temperatures ranging from -40 °C to 70 °C, ensuring durability and reliability in various environments.
| Feature | Description |
|---|---|
| Model | PXI-4130 |
| Part Number | 779647-30, 779647-31 |
| Form Factor | Single slot, 3U PXI module |
| Output Range | ±20 V |
| Power Output | Up to 40 W in quadrants I and III, Up to 10 W in quadrants II and IV |
| Current Measurement Resolution | Down to 1 nA |
| Utility Channel Output | Up to 6 V and 1 A |
| Programming Software | NI-DCPower, LabVIEW, LabWindows/CVI |
| Warm-Up Time | 30 minutes |
| Calibration Period | Annually or every two years (recommended) |
| Weight | 11 oz |
| Dimensions | 8.5 x 5.1 x 0.8 in |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -40 °C to 70 °C |
| Humidity Range |
Question 1: What is the output range of the PXI-4130? Question 2: What is the max power output of the PXI-4130? Question 3: What is the current measurement resolution of the PXI-4130? Question 4: What programming software is the PXI-4130 compatible with? Question 5: What is the warm-up time for optimal performance of the PXI-4130? |