img

197596C-02L

This device features a hi-speed USB connection, a 30-minute warm-up time, and supports various part numbers including 780055-01.

In Stock | Ships Today

img

    Description

    The product features a variety of Part Numbers including 780055-01, 780056-06, 780056-01, 780055-04, and 780056-04, ensuring a wide range of options for specific needs. It utilizes a Hi-Speed USB port for connectivity, offering quick and efficient data transfer and communication capabilities.

    The device requires a Warm-up Time of 30 minutes to reach operational readiness, ensuring accuracy and reliability in its performance. It has a recommended Calibration Interval of 2 years, helping to maintain long-term precision and accuracy in its measurements.

    The Maximum Working Voltage is specified at 11 V, which includes both signal and common mode voltage, ensuring safe and optimal performance. It operates within a Power Supply Requirement of 11 to 30 VDC, providing flexibility in various operational environments.

    It supports Four Signal Streams, including Analog input and output, as well as Digital input and output, offering versatility in handling diverse signal types. The device is equipped with Two 32-bit general-purpose Counters/Timers, enhancing its utility for a wide range of applications.

    The Counter Base Clock Frequencies include Internal options of 80 MHz, 20 MHz, and 0.1 MHz; and an External range from 0 MHz to 20 MHz, offering comprehensive timing solutions. It features One Analog Trigger with 10-bits resolution, supporting both Analog Edge and Window Triggering for precise event capture.

    With 16 differential or 32 single-ended Analog Input Channels and an 18-bits ADC resolution, the product offers considerable flexibility and high resolution in data acquisition. It also boasts 4 Analog Output Channels with 16-bits DAC resolution, enabling precise control and output signal generation.

    The device’s Sample Rate capabilities include up to 625 kS/s for Single channel operation and 500 kS/s for Multiple channels, ensuring efficient data handling and processing speeds.

    Question 1: What is the warm-up time for the USB-6289?
    Answer 1: 30 minutes

    Question 2: What is the calibration interval for the USB-6289?
    Answer 2: 2 years

    Question 3: What is the max working voltage of the USB-6289?
    Answer 3: 11 V

    Question 4: How many analog input channels does USB-6289 have?
    Answer 4: 16 differential or 32 single-ended

    Question 5: What is the sample rate for a single channel on the USB-6289?
    Answer 5: Up to 625 kS/s

    Specification Details
    Part Numbers 780055-01, 780056-06, 780056-01, 780055-04, 780056-04
    Connection Hi-Speed USB port
    Warm-up Time 30 minutes
    Calibration Interval 2 years
    Maximum Working Voltage 11 V (includes signal and common mode voltage)
    Power Supply Requirement 11 to 30 VDC
    Signal Streams Four (Analog input and output, Digital input and output)
    Counters/Timers Two 32-bit general-purpose
    Counter Base Clock Frequencies Internal: 80 MHz, 20 MHz, 0.1 MHz; External: 0 MHz to 20 MHz
    Analog Trigger One, 10-bits resolution (Analog Edge and Window Triggering)
    Analog Input Channels 16 differential or 32 single-ended, 18-bits ADC resolution
    Analog Output Channels 4, 16-bits DAC resolution
    Sample Rate Single channel: 625 kS/s; Multiple channels: 500 kS/s