Description
The product comes with a variety of Part Numbers, including 783733-01, 779334-01, and 779334-02, making it versatile for different applications. It is equipped with a 4-Channel capability, allowing for multiple measurements or controls to be taken simultaneously.
The system offers a high Resolution of 16-Bit, ensuring that the data captured is detailed and precise. The Current Output Range is quite flexible, ranging from 0 mA to 20 mA, suitable for a wide array of industrial applications. Moreover, it can handle a Maximum Output Load of up to 600 Ω, making it robust for various electrical loads.
Its Update Rate is impressively fast, at 12 μs when used with R Series Chassis and even quicker at 9.5 μs with Other Chassis types. This feature ensures that data is processed and updated rapidly, minimizing delays in system responses. The device operates on a Power Supply range of 9 VDC to 36 VDC, providing flexibility in terms of power sources. Additionally, it is designed with Overvoltage Protection of ±40 V, safeguarding the device against unexpected power surges.
The operating environment for this product is quite extensive, with an Operating Temperature Range of -40 °C to 70 °C and a Storage Temperature Range of -40 °C to 85 °C. It can operate and be stored in a wide Humidity Range, from 10% RH to 90% RH when operating, and 5% RH to 95% RH for storage, ensuring reliability in various environmental conditions. Additionally, it is capable of withstanding Vibration (Operating) up to 5 grms, 5 g (10 to 500 Hz), highlighting its durability.
Compatibility is key for this product, as it supports various Software platforms such as NIDAQmx, LabVIEW, LabWindows/CVI, and ANSI C.
| Specification | Detail |
|---|---|
| Part Numbers | 783733-01, 779334-01, 779334-02 |
| Channels | 4-Channel |
| Resolution | 16-Bit |
| Current Output Range | 0 mA to 20 mA |
| Maximum Output Load | 600 Ω |
| Update Rate | 12 μs (R Series Chassis), 9.5 μs (Other Chassis) |
| Power Supply | 9 VDC to 36 VDC |
| Overvoltage Protection | ±40 V |
| Operating Temperature Range | -40 °C to 70 °C |
| Storage Temperature Range | -40 °C to 85 °C |
| Humidity Range (Operating and Storage) | 10% RH to 90% RH, 5% RH to 95% RH |
| Vibration (Operating) | 5 grms, 5 g (10 to 500 Hz) |
| Software Compatibility | NIDAQmx, LabVIEW, LabWindows/CVI, ANSI C |
| Weight | 4.8 oz |
| Calibration | Available, with recommended periods |
| Connection Types | Screw Terminals, Spring Terminals, Conformal Coated Screw Terminals |
Question 1: What is the current output range of the NI-9265?
Answer 1: 0 mA to 20 mA
Question 2: What is the resolution of the NI-9265?
Answer 2: 16-Bit
Question 3: What is the operating temperature range for the NI-9265?
Answer 3: -40°C to 70°C
Question 4: What software platforms does the NI-9265 support?
Answer 4: NIDAQmx, LabVIEW, LabWindows/CVI, ANSI C
Question 5: What power supply range does the NI-9265 operate on?
Answer 5: 9 VDC to 36 VDC