img

198848F-04L

The NI-9219 is a universal analog input module for NI CompactDAQ or CompactRIO systems, supporting a wide range of sensors with a max voltage of ±60 V.

In Stock | Ships Today

img

    Description

    The NI-9219 is a versatile Universal Analog Input Module designed for a wide array of applications, including but not limited to, working with strain gages, RTDs, thermocouples, load cells, and powered sensors. This module falls within the C Series Analog Input category and is compatible with NI CompactDAQ or CompactRIO Chassis systems.

    The module comes in two versions, the conformal coated version with the part number 779781-02 and the non-conformal coated version with the part number 785994-01. Other part numbers associated with this module include 192496F-01L and 198848F-04L, allowing for flexibility in replacing or expanding your existing systems.

    With its ability to handle input types such as strain gages, RTDs, thermocouples, load cells, and powered sensors, the NI-9219 is incredibly versatile. It can manage a maximum voltage of ±60 V and a maximum current of ±25 mA, making it suitable for a wide range of measurement tasks. The module boasts a maximum sample rate of 100 S/s per channel, ensuring precise and timely data collection.

    Connectivity is achieved through a Spring Terminal connector, providing secure and reliable connections. The module offers isolation of 250 Vrms Ch-Ch, ensuring safety and reducing noise interference between channels. Furthermore, it is designed to operate within a temperature range of -40 °C to 70 °C, making it suitable for use in a variety of environmental conditions.

    To utilize the NI-9219, the NI-DAQmx driver software is required, ensuring compatibility and ease of integration with a wide range of systems and applications. Whether you’re conducting laboratory research, industrial monitoring, or any other precision measurement task, the NI-9219 offers the performance and flexibility needed to meet your requirements.

    < Question 1: What is the max voltage the NI-9219 can handle?
    Answer 1: ±60 V

    Question 2: Can the NI-9219 be used with RTDs?
    Answer 2: Yes, it supports RTDs.

    Question 3: What is the max sample rate per channel for the NI-9219?
    Answer 3: 100 S/s per channel

    Question 4: What type of connector does the NI-9219 use?
    Answer 4: Spring Terminal connector

    Question 5: Is the NI-9219 compatible with CompactDAQ systems?
    Answer 5: Yes, it’s compatible with CompactDAQ systems.

    Specification Detail
    Part Numbers 785994-01, 779781-02, 192496F-01L, 198848F-04L
    Category C Series Analog Input
    Model NI-9219
    Description Universal Analog Input Module
    Compatibility NI CompactDAQ or CompactRIO Chassis
    Conformal Coated Version Part Number 779781-02
    Non-Conformal Coated Version Part Number 785994-01
    Input Types Strain gages, RTDs, thermocouples, load cells, powered sensors
    Maximum Voltage ±60 V
    Maximum Current ±25 mA
    Connectivity Spring Terminal connector
    Isolation 250 Vrms Ch-Ch
    Maximum Sample Rate 100 S/s per channel
    Temperature Range -40 °C to 70 °C
    Software Requirement NI-DAQmx driver