Description
The product described by this technical specification table comes with a range of part numbers including 780493-01, 780493-02, 785185-01, and 785185-02, ensuring a variety of options for specific requirements. It is compatible with both CompactDAQ and CompactRIO platforms, making it versatile for different types of data acquisition and control systems.
This device boasts a 16-channel count, providing ample inputs for various sensors or signals. It offers a maximum accuracy of ±2.25°C, ensuring reliable and precise measurements. With a sample rate of 75 samples per second, it can adequately capture fast-changing signals for thorough analysis.
An important feature of this product is its autozero function, which enhances measurement accuracy by automatically correcting the DC offset. It also provides isolation of 250 Vrms Ch-Earth Continuous to protect the device and measurements from high voltage and noise. The device utilizes spring terminals for easy and secure connections.
To combat interference, it includes noise filtering for both 50 Hz and 60 Hz, ensuring clean and reliable signal measurements. Despite its capabilities, the device remains lightweight at just 5.6 oz, making it convenient for portable applications.
It supports high-resolution and high-speed timing modes, offering flexibility in measurement precision and speed. The device is compatible with the NI-DAQmx driver software, which facilitates easy integration and development with various software packages. These packages include but are not limited to the LabVIEW Professional Development System for Windows, NI LabVIEW FPGA Module, NI LabVIEW Real-Time Module, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, Borland C++, and Microsoft .NET.
The device can be configured via the Measurement & Automation Explorer (MAX), simplifying setup and customization. To maintain its high performance, a recommended calibration interval of at least one year is advised.
Featuring a 24-bit Delta-Sigma ADC type, it ensures high-resolution data conversion. It operates efficiently across a wide temperature
| Specification | Detail |
|---|---|
| Part Numbers | 780493-01, 780493-02, 785185-01, 785185-02 |
| Compatible Platforms | CompactDAQ, CompactRIO |
| Channel Count | 16 |
| Maximum Accuracy | ±2.25°C |
| Sample Rate | 75 Samples per Second |
| Autozero Function | Yes |
| Isolation | 250 Vrms Ch-Earth Continuous |
| Terminal Type | Spring Terminal |
| Noise Filtering | 50 Hz and 60 Hz |
| Weight | 5.6 oz |
| Timing Modes | High-resolution, High-speed |
| Driver Software | NI-DAQmx |
| Compatible Software Packages | LabVIEW Professional Development System for Windows, NI LabVIEW FPGA Module, NI LabVIEW Real-Time Module, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, Borland C++, Microsoft .NET |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Recommended Calibration Interval | At least one year |
| ADC Type | 24-bit Delta-Sigma |
| Operating Temperature | -40°C to 70°C |
| Warm-up Time | 15 minutes |
| Voltage Measurement Range | ±78.125 mV |
| Input Current | 50 nA |
Question 1: How many channels does the NI-9213 have?
Answer 1: 16 channels
Question 2: What is the sampling rate of NI-9213?
Answer 2: 75 samples per second
Question 3: What platforms is the NI-9213 compatible with?
Answer 3: CompactDAQ and CompactRIO
Question 4: What type of ADC does the NI-9213 utilize?
Answer 4: 24-bit Delta-Sigma ADC
Question 5: What is the recommended calibration interval for the NI-9213?
Answer 5: At least one year