img

198854D-06L

The NI-9213 is a C Series Analog Input module with 16 channels, 75 S/s, and 24-bit accuracy, featuring spring terminals and 250 Vrms isolation.

In Stock | Ships Today

img

    Description

    The NI-9213 is a model within the C Series Analog Input category, featuring a variety of part numbers including 780493-01, 780493-02, 785185-01, and 785185-02. This module is specifically designed for temperature measurement, offering 16 channels with a 24-bit resolution and a sample rate of 75 Samples per second for accurate data collection. The NI 9213 boasts a maximum accuracy of 2.25 degrees Celsius, ensuring precise temperature readings.

    It includes 250 Vrms Ch-Earth isolation continuous, which enhances its reliability in various industrial environments. The module operates efficiently within a temperature range of -40 °C to 70 °C, with a warm-up time of 15 minutes before reaching optimal performance levels. Additionally, its voltage measurement range is ±78.125 mV, and it has an input current of 50 nA, making it versatile for a wide range of applications.

    The NI 9213 is equipped with spring terminals, facilitating easy and secure connections without the need for additional tools. Weighing only 5.6 oz, this module is lightweight yet robust, designed to withstand the demands of industrial environments. For maintaining its accuracy and performance, a recommended calibration interval of at least one year is advised. Furthermore, it is compatible with NI-DAQ software, allowing for seamless integration with existing systems and straightforward data management and analysis.

    Specification Details
    Part Numbers 780493-01, 780493-02, 785185-01, 785185-02
    Category C Series Analog Input
    Model NI-9213
    Description NI 9213 Spring, 16-ch TC, 24-bit, 75 S/s AI module
    Channels 16
    Maximum Accuracy 2.25 degrees Celsius
    Sample Rate 75 Samples per second
    Isolation 250 Vrms Ch-Earth isolation continuous
    Terminal Type Spring terminal
    Weight 5.6 oz
    Operating Temperature -40 °C to 70 °C
    Warm-up Time 15 minutes
    Voltage Measurement Range ±78.125 mV
    Input Current 50 nA
    Recommended Calibration Interval At least one year
    Software Compatibility NI-DAQ

    Question 1: What’s the sample rate of the NI-9213?
    Answer 1: 75 Samples per second

    Question 2: How many channels does the NI-9213 have?
    Answer 2: 16 channels

    Question 3: What’s the resolution of the NI-9213?
    Answer 3: 24-bit

    Question 4: What is the isolation rating for the NI-9213?
    Answer 4: 250 Vrms Ch-Earth isolation

    Question 5: What’s the recommended calibration interval for the NI-9213?
    Answer 5: At least one year