Description
The product comes with a variety of part numbers, including 780493-01, 780493-02, 785185-01, and 785185-02, designed to cater to a range of applications. It features 16 channels, allowing for multi-point measurement and control. The device boasts a maximum accuracy of ±2.25°C, ensuring precise data collection for critical applications.
With a sample rate of 75 S/s, it facilitates timely data acquisition, suitable for dynamic systems monitoring. The product provides 250 Vrms channel-to-earth continuous isolation, enhancing safety and signal integrity in electrically noisy environments. Its spring terminal type ensures easy and secure connections, promoting reliability and longevity.
The inclusion of an autozero function further refines measurement accuracy by compensating for offset errors. It is equipped to handle 50 Hz and 60 Hz noise filtering, minimizing interference and improving signal clarity. Despite its advanced features, the device remains lightweight at only 5.6 oz, making it suitable for portable applications.
It supports both high-resolution and high-speed timing modes, providing flexibility in data capture according to application requirements. The device is compatible with a wide range of software including LabVIEW, LabWindows/CVI, Microsoft Visual C++, Visual Basic, Borland C++, and .NET, ensuring easy integration into existing systems. Configuration is facilitated through the Measurement & Automation Explorer (MAX), simplifying setup and customization.
To maintain its precision, a recommended calibration interval of at least one year is advised. It operates effectively within a temperature range of -40°C to 70°C, suited for harsh environments. A warm-up time of 15 minutes is necessary for the device to stabilize and achieve accurate measurements. The voltage measurement range is ±78.125 mV, and it operates with an input current of 50 nA,
| Specification | Detail |
|---|---|
| Part Numbers | 780493-01, 780493-02, 785185-01, 785185-02 |
| Channels | 16 |
| Maximum Accuracy | ±2.25°C |
| Sample Rate | 75 S/s |
| Isolation | 250 Vrms Ch-Earth Continuous |
| Terminal Type | Spring Terminal |
| Autozero Function | Yes |
| Filtering | 50 Hz and 60 Hz noise |
| Weight | 5.6 oz |
| Timing Modes | High-resolution and High-speed |
| Software Compatibility | LabVIEW, LabWindows/CVI, Microsoft Visual C++, Visual Basic, Borland C++, .NET |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Recommended Calibration Interval | At least one year |
| Operating Temperature | -40°C to 70°C |
| Warm-up Time | 15 minutes |
| Voltage Measurement Range | ±78.125 mV |
| Input Current | 50 nA |
| Calibration Options | NIST accredited calibrations available |
Question 1: How many channels does the NI-9213 have?
Answer 1: 16 channels
Question 2: What is the NI-9213’s maximum accuracy?
Answer 2: ±2.25°C
Question 3: What sample rate does the NI-9213 offer?
Answer 3: 75 S/s
Question 4: What types of noise can the NI-9213 filter?
Answer 4: 50 Hz and 60 Hz
Question 5: What software is the NI-9213 compatible with?
Answer 5: LabVIEW, .NET, Visual C++, and more