Description
The product comes with Part Numbers 780264-01, 779521-01, and 780264-02, catering to a variety of requirements and setups.
It features 4 Channels, which allow for multiple data acquisition streams simultaneously, enhancing the efficiency and capability of data collection and monitoring systems.
With a Sample Rate of 50 kS/s per channel, it ensures rapid data collection with minimal lag, making it ideal for high-speed applications.
The ADC Resolution is an impressive 24 bits, offering high precision and accuracy in data conversion from analog to digital form.
For connectivity, the device supports RJ-50 and DSUB connectors, providing flexible options for integrating with various types of hardware and systems.
Among the available part numbers, only 780264-02 is Conformal Coated, offering enhanced protection against environmental factors, while the others are not coated.
The product ensures safety and reliability with Isolation rated at 60 VDC and 1000 Vrms transient, safeguarding against unexpected voltage spikes.
It also features Remote Sensing Capability, allowing for more accurate measurements by compensating for voltage drops in the measurement path.
Shunt Calibration is available, enabling users to verify and calibrate measurement accuracy easily.
For software integration, it is compatible with NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++, Microsoft Visual Basic, Microsoft .NET, and Borland C++, offering a broad range of development options.
The recommended Calibration Frequency is annually or every two years, ensuring that the device maintains its accuracy and reliability over time.
| Specification | Detail |
|---|---|
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Channels | 4 |
| Sample Rate | 50 kS/s per channel |
| ADC Resolution | 24 bits |
| Connectivity Options | RJ-50, DSUB connectors |
| Conformal Coated | 780264-02 (Yes), Others (No) |
| Isolation | 60 VDC, 1000 Vrms transient |
| Remote Sensing Capability | Yes |
| Shunt Calibration | Yes |
| Software Compatibility | NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++, Microsoft Visual Basic, Microsoft .NET, Borland C++ |
| Calibration Frequency | Annually or every two years (Recommended) |
Question 1: How many channels does the NI-9237 have?
Answer 1: It has 4 channels.
Question 2: What is the sample rate per channel for the NI-9237?
Answer 2: 50 kS/s per channel.
Question 3: What ADC resolution does the NI-9237 offer?
Answer 3: 24 bits.
Question 4: Is the 780264-02 part number conformal coated?
Answer 4: Yes, it is conformal coated.
Question 5: Does the NI-9237 have remote sensing capability?
Answer 5: Yes, it has remote sensing capability.