Description
The product with part numbers 780264-01, 779521-01, 780264-02 features a robust design tailored to meet the needs of demanding applications. Each unit is equipped with 4 channels, ensuring versatile connectivity options for various sensors and inputs.
Offering an impressive sample rate of 50 kS/s per channel, this device guarantees high-speed data acquisition, enabling precise and real-time analysis. The 24-bit ADC resolution further enhances its performance by providing high-resolution measurements, ensuring accurate data capture even in the most intricate applications.
Connectivity is versatile with the inclusion of RJ-50 and DSUB connectors, facilitating easy and reliable connections to a wide range of devices and sensors. The 780264-02 model is distinguished by its conformal coating, offering additional protection against environmental factors, making it suitable for harsh conditions.
The device boasts 60 VDC, 1000 Vrms transient isolation, ensuring the safety and integrity of measurements by preventing ground loops and protecting against voltage spikes. With remote sensing capability and shunt calibration, users benefit from enhanced accuracy and simplified setup processes, facilitating more efficient operations.
Software compatibility is extensive, supporting NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++, offering flexibility in programming environments and ensuring seamless integration into existing systems.
To maintain optimal performance and reliability, it is recommended to undergo calibration annually or every two years, ensuring that the device continues to deliver accurate and reliable data over time.
| Specification | Details |
|---|---|
| Part Numbers | 780264-01, 779521-01, 780264-02 |
| Channels | 4 |
| Sample Rate | 50 kS/s per channel |
| ADC Resolution | 24 bits |
| Connectors | RJ-50, DSUB |
| Conformal Coating | Available on 780264-02 |
| Isolation | 60 VDC, 1000 Vrms transient |
| Remote Sensing Capability | Yes |
| Shunt Calibration | Yes |
| Software Compatibility | NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++ 6.0, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++ |
| Recommended Calibration Period | Annually or every two years |
Question 1: How many channels does the NI-9237 have?
Answer 1: It has 4 channels.
Question 2: What is the sample rate of the NI-9237?
Answer 2: 50 kS/s per channel.
Question 3: What type of connectors are used with the NI-9237?
Answer 3: RJ-50 and DSUB connectors.
Question 4: What is the ADC resolution of the NI-9237?
Answer 4: 24-bit.
Question 5: Is the NI-9237 compatible with Microsoft .NET?
Answer 5: Yes, it’s compatible.