Description
The product with part numbers 781098-01 and 781098-02 boasts a high-resolution output of 16-bit, ensuring detailed and precise measurements for various applications. This device features 4 analog output channels, enabling it to manage multiple signals simultaneously for efficient data handling.
It supports a maximum sampling rate of 100 kS/s per channel, which allows for high-speed data acquisition, making it ideal for dynamic and demanding applications. Additionally, this device offers channel-to-channel isolation, enhancing the accuracy and reliability of each signal by preventing cross-channel interference.
The output voltage range is specified as ±10 V, providing sufficient flexibility for a wide range of applications. Moreover, it has a current drive capability of ±10 mA per channel, with a total of ±20 mA for all channels, ensuring it can drive a variety of sensors and actuators.
Software support is comprehensive, including compatibility with the LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, and LabVIEW Real-Time Module. This ensures that users can easily integrate the device into their existing LabVIEW environments for seamless operation and development.
The device is also supported by NI CompactDAQ as of NI-DAQmx Version 9.1, offering further versatility and ease of use in data acquisition systems. The recommended operating temperature range of -40 °C to 70 °C underscores its reliability and robustness in harsh environments.
With a weight of just 5.5 oz., this device is lightweight yet durable. Calibration services are available, with an average turnaround time of 1 to 2 weeks for NIST accredited calibrations, ensuring that the device maintains its precision and accuracy over time.
| Specification | Detail |
|---|---|
| Part Numbers | 781098-01, 781098-02 |
| Resolution | 16-bit |
| Number of Channels | 4 analog output channels |
| Maximum Sampling Rate | 100 kS/s per channel |
| Channel-to-Channel Isolation | Yes |
| Output Voltage Range | ±10 V |
| Current Drive Capability | ±10 mA per channel, total of ±20 mA for all channels |
| Software Support | LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, LabVIEW Real-Time Module |
| NI CompactDAQ Support | Yes, as of NI-DAQmx Version 9.1 |
| Recommended Operating Temperature Range | -40 °C to 70 °C |
| Weight | 5.5 oz. |
| Calibration | Available, with an average turnaround time of 1 to 2 weeks for NIST accredited calibrations |
Question 1: What resolution is the NI-9269 capable of?
Answer 1: 16-bit
Question 2: How many output channels does the NI-9269 have?
Answer 2: 4 analog output channels
Question 3: What is the maximum sampling rate of the NI-9269?
Answer 3: 100 kS/s per channel
Question 4: Can the NI-9269 be integrated with LabVIEW?
Answer 4: Yes, supports LabVIEW
Question 5: What is the operating temperature range for the NI-9269?
Answer 5: -40 °C to 70 °C