Description
The product features Part Numbers 781098-01 and 781098-02, designed to cater to a variety of applications requiring precision and reliability. It boasts a Resolution of 16-bit, ensuring high-quality output and performance.
With 4 analog output channels, this device is capable of handling multiple signals simultaneously, making it versatile for different uses. The Maximum Sampling Rate is 100 kS/s per channel, which allows for fast data acquisition and processing.
One of the key features is its Channel-to-Channel Isolation, which ensures that each channel operates independently without interference, enhancing the accuracy and reliability of the outputs. The Output Voltage Range is ±10 V, and each channel can deliver an Output Current of ±10 mA maximum, with a Total Output Current capacity of ±20 mA.
The device is lightweight, at just 5.5 oz., and has a robust Operating Temperature Range of -40 °C to 70 °C, ensuring reliable performance in diverse environments. It supports a range of software including the LabVIEW Professional Development System, LabVIEW FPGA Module, and LabVIEW Real-Time Module, providing flexibility and ease of use for various applications.
For optimal performance, the Recommended Accessories include the NI-9971 Backshell Kit. Additionally, the device offers Calibration Availability through Apex Waves, with a Calibration Period recommended annually or every two years to maintain precision and accuracy.
| Specification | Detail |
|---|---|
| Part Numbers | 781098-01, 781098-02 |
| Resolution | 16-bit |
| Number of Channels | 4 analog output channels |
| Maximum Sampling Rate | 100 kS/s per channel |
| Channel-to-Channel Isolation | Yes |
| Output Voltage Range | ±10 V |
| Output Current (per channel) | ±10 mA maximum |
| Total Output Current | ±20 mA |
| Weight | 5.5 oz. |
| Operating Temperature Range | -40 °C to 70 °C |
| Software Support | LabVIEW Professional Development System, LabVIEW FPGA Module, LabVIEW Real-Time Module |
| Recommended Accessories | NI-9971 Backshell Kit |
| Calibration Availability | Yes, through Apex Waves |
| Calibration Period | Annually or every two years (recommended) |
Question 1: What’s the resolution of the NI-9269?
Answer 1: 16-bit
Question 2: How many analog output channels does NI-9269 have?
Answer 2: 4 channels
Question 3: What is the maximum sampling rate per channel for NI-9269?
Answer 3: 100 kS/s
Question 4: What’s the total output current capacity of NI-9269?
Answer 4: ±20 mA
Question 5: What are the recommended accessories for NI-9269?
Answer 5: NI-9971 Backshell Kit