    Description

    The product comes with part numbers 781098-01 and 781098-02, ensuring a wide range of options for various applications. It boasts a high resolution of 16-bit, providing precise and accurate output for sophisticated needs. Users will benefit from its 4 analog output channels, allowing for multiple data outputs simultaneously.

    With a maximum sampling rate of 100 kS/s per channel, it ensures rapid data acquisition, making it suitable for high-speed applications. Additionally, it features channel-to-channel isolation, enhancing the integrity of the data by preventing channel crosstalk.

    The device supports an output voltage range of ±10 V, offering flexibility in a wide range of applications. Its current drive capability is impressive, with ±10 mA maximum per channel, with the total output current limited to ±20 mA, ensuring safe and reliable operation.

    For software integration, it is compatible with the LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, and LabVIEW Real-Time Module, providing a comprehensive development environment. It is also supported by NI CompactDAQ as of NI-DAQmx Version 9.1, ensuring seamless integration with existing setups.

    The product is lightweight at only 5.5 oz., making it easy to handle and install. It operates within a wide temperature range of -40 °C to 70 °C, ensuring reliability under extreme conditions. For calibration, it offers options for NIST accredited calibrations through a 3rd party, as well as in-house calibration to manufacturer specifications, ensuring continued accuracy and performance.

    Specification Details
    Part Numbers 781098-01, 781098-02
    Resolution 16-bit
    Number of Channels 4 analog output channels
    Maximum Sampling Rate 100 kS/s per channel
    Channel-to-Channel Isolation Yes
    Output Voltage Range ±10 V
    Current Drive Capability ±10 mA maximum per channel, total output current limited to ±20 mA
    Software Support LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, LabVIEW Real-Time Module
    Supported by NI CompactDAQ Yes, as of NI-DAQmx Version 9.1
    Weight 5.5 oz.
    Recommended Operating Temperature -40 °C to 70 °C
    Calibration Options NIST accredited calibrations through a 3rd party, In-house calibration to manufacturer specifications

    Question 1: What is the resolution of the NI-9269?
    Answer 1: 16-bit

    Question 2: How many analog output channels does the NI-9269 have?
    Answer 2: 4 channels

    Question 3: What is the max sampling rate per channel for the NI-9269?
    Answer 3: 100 kS/s

    Question 4: What output voltage range does the NI-9269 support?
    Answer 4: ±10 V

    Question 5: Is the NI-9269 compatible with LabVIEW?
    Answer 5: Yes, supports LabVIEW