Description
The product comes with part numbers 781098-01 and 781098-02, ensuring a wide range of options for various applications. It boasts a high resolution of 16-bit, providing precise and accurate output for sophisticated needs. Users will benefit from its 4 analog output channels, allowing for multiple data outputs simultaneously.
With a maximum sampling rate of 100 kS/s per channel, it ensures rapid data acquisition, making it suitable for high-speed applications. Additionally, it features channel-to-channel isolation, enhancing the integrity of the data by preventing channel crosstalk.
The device supports an output voltage range of ±10 V, offering flexibility in a wide range of applications. Its current drive capability is impressive, with ±10 mA maximum per channel, with the total output current limited to ±20 mA, ensuring safe and reliable operation.
For software integration, it is compatible with the LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, and LabVIEW Real-Time Module, providing a comprehensive development environment. It is also supported by NI CompactDAQ as of NI-DAQmx Version 9.1, ensuring seamless integration with existing setups.
The product is lightweight at only 5.5 oz., making it easy to handle and install. It operates within a wide temperature range of -40 °C to 70 °C, ensuring reliability under extreme conditions. For calibration, it offers options for NIST accredited calibrations through a 3rd party, as well as in-house calibration to manufacturer specifications, ensuring continued accuracy and performance.
| Specification | Details |
|---|---|
| Part Numbers | 781098-01, 781098-02 |
| Resolution | 16-bit |
| Number of Channels | 4 analog output channels |
| Maximum Sampling Rate | 100 kS/s per channel |
| Channel-to-Channel Isolation | Yes |
| Output Voltage Range | ±10 V |
| Current Drive Capability | ±10 mA maximum per channel, total output current limited to ±20 mA |
| Software Support | LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, LabVIEW Real-Time Module |
| Supported by NI CompactDAQ | Yes, as of NI-DAQmx Version 9.1 |
| Weight | 5.5 oz. |
| Recommended Operating Temperature | -40 °C to 70 °C |
| Calibration Options | NIST accredited calibrations through a 3rd party, In-house calibration to manufacturer specifications |
Question 1: What is the resolution of the NI-9269?
Answer 1: 16-bit
Question 2: How many analog output channels does the NI-9269 have?
Answer 2: 4 channels
Question 3: What is the max sampling rate per channel for the NI-9269?
Answer 3: 100 kS/s
Question 4: What output voltage range does the NI-9269 support?
Answer 4: ±10 V
Question 5: Is the NI-9269 compatible with LabVIEW?
Answer 5: Yes, supports LabVIEW