img

198921D-02L

The PXIe-6358 is a PXI multifunction DAQ with 16 differential analog input channels, 16-bit ADC, and a 1.25 MS/s sample rate per channel.

In Stock | Ships Today

img

    Description

    The PXI Multifunction DAQ model PXIe-6358 is a high-performance data acquisition system with a part number of 198921D-02L and an alternate part number of 781054-01. This model is designed to provide exceptional accuracy and functionality for a wide range of applications.

    It features 16 differential analog input channels with an ADC resolution of 16 bits, ensuring high-quality data capture. The DAQ operates at a sample rate of 1.25 MS/s per channel, allowing for the efficient processing of signals. Its Common-Mode Rejection Ratio (CMRR) is 75 dB, and it boasts a low Total Harmonic Distortion (THD) of -80 dBFS, ensuring the integrity of the signal is maintained.

    The timing accuracy is maintained at 50 ppm of the sample rate, guaranteeing precise data acquisition and synchronization. Power requirements for the PXIe-6358 are 7.8 W at +3.3 V and 22.2 W at +12 V, making it an energy-efficient choice for many systems. The unit also supports analog triggers for flexible system integration and operation.

    Input impedance is rated at 10 kilo-ohms, and the device includes 2 68-pin VHDCI connectors for easy and reliable connections. To achieve optimal performance, a recommended warm-up time of 15 minutes is advised, along with a calibration period of at least once every 2 years to maintain accuracy and reliability.

    Question 1: What is the ADC resolution of the PXIe-6358?
    Answer 1: 16 bits

    Question 2: How many differential analog input channels does the PXIe-6358 have?
    Answer 2: 16 channels

    Question 3: What is the sample rate per channel for the PXIe-6358?
    Answer 3: 1.25 MS/s

    Question 4: What is the power requirement at +12 V for the PXIe-6358?
    Answer 4: 22.2 W

    Question 5: How often should the PXIe-6358 be calibrated?
    Answer 5: Once every 2 years

    Specification Detail
    Part Number 198921D-02L
    Alternate Part Number 781054-01
    Category PXI Multifunction DAQ
    Model PXIe-6358
    Analog Input Channels 16 differential
    ADC Resolution 16 bits
    Sample Rate 1.25 MS/s per channel
    CMRR 75 dB
    Total Harmonic Distortion -80 dBFS
    Timing Accuracy 50 ppm of the sample rate
    Power Requirement 7.8 W at +3.3 V and 22.2 W at +12 V
    Analog Triggers Yes
    Input Impedance 10 kilo-ohms
    I/O Connectors 2 68-pin VHDCI
    Recommended Warm-Up Time 15 minutes
    Recommended Calibration Period At least once every 2 years