198924A-02L

The PXIe-6358 is a PXI Multifunction DAQ with 16 differential analog input channels and a 1.25 MS/s sample rate per channel.

In Stock | Ships Today

img

    Description

    The Part Number 781054-01 refers to a PXI Multifunction DAQ device, specifically the model PXIe-6358. This device is equipped with 16 differential analog input channels, ensuring a wide range of signal acquisition capabilities. It boasts an ADC (Analog-to-Digital Converter) resolution of 16 bits, allowing for precise data conversion.

    With a sample rate of 1.25 MS/s per channel, the PXIe-6358 can capture high-speed signals with ease. Its Common-Mode Rejection Ratio (CMRR) stands at 75 dB, which minimizes noise and interference in signal measurements. Furthermore, the device features a Total Harmonic Distortion (THD) of -80 dBFS, ensuring the purity of the captured signals.

    The timing accuracy of the device is 50 ppm of the sample rate, which guarantees precise time-stamping of data. Power requirements for the PXIe-6358 are 7.8 W at +3.3 V and 22.2 W at +12 V, indicating its energy efficiency. Additionally, it supports 16 bits triggering schemes resolution, providing flexibility in various applications.

    The input impedance is 10 kilo-ohms, which is suitable for a wide range of sensors and inputs. Connectivity is facilitated through 2 68-pin VHDCI connectors, allowing for easy integration with other devices. It is important to note that the device requires a warm-up time of 15 minutes before reaching optimal operation conditions.

    For maintenance, a calibration period is recommended at least once every 2 years to ensure sustained accuracy and performance. Lastly, the PXIe-6358 is equipped with 4 analog output channels, offering additional flexibility for signal generation and output.

    Question 1: What is the ADC resolution of PXIe-6358?
    Answer 1: 16 bits

    Question 2: How many analog input channels does PXIe-6358 have?
    Answer 2: 16 differential channels

    Question 3: What is the sample rate per channel for PXIe-6358?
    Answer 3: 1.25 MS/s

    Question 4: What are the power requirements for PXIe-6358?
    Answer 4: 7.8 W at +3.3 V and 22.2 W at +12 V

    Question 5: How often is calibration recommended for PXIe-6358?
    Answer 5: At least once every 2 years

    Specification Detail
    Part Number 781054-01
    Category PXI Multifunction DAQ
    Model PXIe-6358
    Analog Input Channels 16 differential
    ADC Resolution 16 bits
    Sample Rate 1.25 MS/s per channel
    CMRR 75 dB
    Total Harmonic Distortion -80 dBFS
    Timing Accuracy 50 ppm of sample rate
    Power Requirement 7.8 W at +3.3 V and 22.2 W at +12 V
    Triggering Schemes Resolution 16 bits
    Input Impedance 10 kilo-ohms
    I/O Connectors 2 68-pin VHDCI
    Warm-up Time 15 minutes
    Calibration Period At least once every 2 years
    Analog Output Channels 4