img

198992D-21L

This device features 4 channels, 50 kS/s sampling, 24-bit ADC, various connectivity, and is compatible with multiple software, requiring annual calibration.

In Stock | Ships Today

img

    Description

    The product features a variety of part numbers including 780264-01, 779521-01, and 780264-02, catering to different specifications and requirements. It is equipped with 4 channels, ensuring multiple input and output options for users.

    With a sample rate of 50 kS/s per channel, it provides high-speed data acquisition, allowing for precise and timely readings. The ADC resolution stands at 24 bits, offering high-resolution data output for more accurate measurements.

    For connectivity, it features RJ-50 and DSUB connectors, providing versatile connection options suitable for various applications. The conformal coated version, indicated by part number 780264-02, offers added protection against harsh environments, while the other versions are not coated.

    The device is designed with 60 VDC, 1000 Vrms transient isolation, ensuring safety and reliability during operation. Additionally, it boasts a remote sensing capability and shunt calibration, enhancing usability and flexibility for different operational needs.

    It is compatible with a wide range of software including NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++, Microsoft Visual Basic 6.0, Microsoft .NET, and Borland C++, making it a versatile tool for various data acquisition and analysis tasks.

    The manufacturer recommends a calibration period of annually or every two years to ensure optimal performance and reliability over time.

    Feature Description
    Part Numbers 780264-01, 779521-01, 780264-02
    Channels 4
    Sample Rate 50 kS/s per channel
    ADC Resolution 24 bits
    Connectivity Options RJ-50, DSUB connectors
    Conformal Coated 780264-02 (Yes), Others (No)
    Isolation 60 VDC, 1000 Vrms transient
    Remote Sensing Capability Yes
    Shunt Calibration Yes
    Software Compatibility NI-DAQmx 8.1 or later, LabVIEW, LabWindows™/CVI™, Microsoft Visual C++, Microsoft Visual Basic 6.0, Microsoft .NET, Borland C++
    Recommended Calibration Period Annually or every two years

    Question 1: What is the sample rate of the NI-9237?
    Answer 1: 50 kS/s per channel.

    Question 2: What type of connectors does the NI-9237 use?
    Answer 2: RJ-50 and DSUB connectors.

    Question 3: Does the NI-9237 require annual calibration?
    Answer 3: Yes, annually or every two years.

    Question 4: What is the ADC resolution of the NI-9237?
    Answer 4: 24 bits.

    Question 5: Is the NI-9237 compatible with LabVIEW?
    Answer 5: Yes, along with other software.