Description
The Part Number 778283-01 specifies a RF Downconverter, specifically the model PXI-5600. This device is designed as a 3U PXI Module, tailored to fit seamlessly within the PXI ecosystem. It boasts a real-time bandwidth of 20 MHz, ensuring robust performance for a wide range of RF applications.
Operating across a frequency range from 9 kHz to 2.7 GHz, the PXI-5600 is versatile and can be deployed in various scenarios requiring precise signal conversion. It features a typical noise density of < -140 dBm/Hz, contributing to its high sensitivity and efficiency in signal processing tasks. Additionally, its spurious-free dynamic range is stated to be > 80 dB, allowing for the accurate detection and measurement of signals amidst potential interference.
The typical phase noise of the module is < -94 dBc/Hz at 10 kHz offset, indicating a low level of phase fluctuation and thus, high signal purity. With a timebase stability of ±20 ppb and a timebase accuracy of ±50 ppb, this module ensures precise timing and synchronization within your measurements.
For software integration, the PXI-5600 requires NI-RFSA 2.1, NIPXI-5600 Support Driver, LabVIEW, LabWindows/CVI, and Microsoft C/C++, providing users with a range of options for application development and data analysis. The module is equipped with multiple connectors including FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, and INPUT, offering flexibility in setup and connectivity.
The warm-up time for the PXI-5600 is set at 20 minutes, after which it operates at its optimal performance level. To maintain accuracy and reliability, a <
| Specification | Detail |
|---|---|
| Part Number | 778283-01 |
| Category | RF Downconverters |
| Model | PXI-5600 |
| Form Factor | 3U PXI Module |
| Real-Time Bandwidth | 20 MHz |
| Frequency Range | 9 kHz to 2.7 GHz |
| Typical Noise Density | < -140 dBm/Hz |
| Spurious-Free Dynamic Range | > 80 dB |
| Typical Phase Noise | < -94 dBc/Hz at 10 kHz offset |
| Timebase Stability | ±20 ppb |
| Timebase Accuracy | ±50 ppb |
| Software Requirements | NI-RFSA 2.1, NIPXI-5600 Support Driver, LabVIEW, LabWindows/CVI, Microsoft C/C++ |
| Connectors | FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT |
| Warm-Up Time | 20 minutes |
| Calibration Period | Annually or
Question 1: What is the bandwidth of the PXI-5600? Question 2: What frequency range does the PXI-5600 cover? Question 3: What is the typical noise density of the PXI-5600? Question 5: What software is required for the PXI-5600? |