img

199541G-02L

The PXIe-5651 with part number 199541G-02L supports a 500 kHz to 3.3 GHz frequency range, <3 Hz resolution, and 12 dBm max output, ideal for varied applications.

In Stock | Ships Today

img

    Description

    The Part Number for this device is 199541G-02L, and it is known as model PXIe-5651. This model operates within a Frequency Range from 500 kHz to 3.3 GHz, offering a Frequency Resolution of less than 3 Hz to 6 Hz. It is capable of delivering a Maximum Output Power of 12 dBm and boasts a Typical Tuning Time of just 1.5 ms.

    The device’s Reference Clock Internal Accuracy is rated at ±3 ppm, with a maximum of ±1 ppm at temperatures ranging from 15 °C to 35 °C. Its Internal Reference Output Frequency is 10 MHz, and it features an Output Impedance of 50 Ω. Regarding its output capabilities, the amplitude it can produce is 1 Vpk-pk into 50 Ω.

    For external referencing, the External Reference Input Frequency should be 10 MHz ±10 ppm, with an Input Impedance also at 50 Ω. The External Reference Input Amplitude supported ranges from 0.2 Vpk-pk to 1.5 Vpk-pk into 50 Ω.

    Its Power Requirement is 1 A max at +3.3 V and +12 V, and it is recommended that the device is given a Warm-Up Time of 30 minutes before full operation. To ensure optimal performance, a Calibration Period of at least once a year is recommended.

    This model is compatible with several Software Packages/ADEs, including LabVIEW, LabWindows/CVI, and Measurement Studio. For configuration

    Specification Details
    Part Number 199541G-02L
    Model PXIe-5651
    Frequency Range 500 kHz to 3.3 GHz
    Frequency Resolution <3 Hz to 6 Hz
    Maximum Output Power 12 dBm
    Typical Tuning Time 1.5 ms
    Reference Clock Internal Accuracy ±3 ppm, ±1 ppm max at 15 °C to 35 °C
    Internal Reference Output Frequency 10 MHz
    Output Impedance 50 Ω
    Amplitude 1 Vpk-pk into 50 Ω
    External Reference Input Frequency 10 MHz ±10 ppm
    Input Impedance 50 Ω
    External Reference Input Amplitude 0.2 Vpk-pk to 1.5 Vpk-pk into 50 Ω
    Power Requirement 1 A max at +3.3 V and +12 V
    Recommended Warm-Up Time 30 minutes
    Calibration Period At least once a year
    Software Packages/ADEs Compatibility LabVIEW, LabWindows/CVI, Measurement Studio
    Configuration Tool Measurement & Automation Explorer (MAX)
    Random Vibration (Non-operating) 5 Hz to

    Question 1: What is the frequency range of PXIe-5651?
    Answer 1: 500 kHz to 3.3 GHz

    Question 2: What is the max output power of the PXIe-5651?
    Answer 2: 12 dBm

    Question 3: What is the frequency resolution of PXIe-5651?
    Answer 3: <3 Hz to 6 Hz Question 4: What is the reference clock accuracy of PXIe-5651?
    Answer 4: ±3 ppm, ±1 ppm between 15 °C and 35 °C

    Question 5: How long is the warm-up time for PXIe-5651?
    Answer 5: 30 minutes