img

199764A-01

The National Instruments USB-5681 is a power sensor with a frequency range of 10 MHz to 18 GHz and measures signals from -40 dBm to +20 dBm.

In Stock | Ships Today

img

    Description

    The product with the part number 781214-01 falls under the category of a Power Sensor. Specifically, it is the USB-5681 model from National Instruments, described as the National Instruments USB-5681 RF Power Sensor Device. This sophisticated device is designed to accommodate a wide frequency range, from 10 MHz to 18 GHz, making it versatile for various applications.

    Its capability to handle input signal strength from -40 dBm to +20 dBm further extends its utility. The measurement ranges of this device are quite comprehensive, spanning from +20 dBm to -7 dBm, and from -7 dBm to -40 dBm, enabling it to cover a broad spectrum of signal strengths with precision.

    The USB-5681 model boasts a bandwidth support of 50 kHz and can achieve a measurement speed of 100 samples per second (S/s). This high speed allows for real-time monitoring and adjustments in various testing scenarios. Moreover, it maintains a typical uncertainty of less than 3%, ensuring accurate measurements.

    Adhering to rigorous safety standards, this power sensor complies with multiple certifications, including IEC 61010-1, EN 61010-1, UL 61010-1, and CSA C22.2 No. 61010-1. Such compliance underscores its reliability and safety for users.

    For its power requirements, the device operates on 5 VDC, drawing 450 mA. It is designed to withstand a maximum voltage at the RF port of ±20 VDC, and it can handle an absolute maximum power of +30 dBm. These specifications ensure that the USB-5681 is both a powerful and resilient tool for professionals working with RF power measurements.

    Specification Detail
    Part Number 781214-01
    Category Power Sensor
    Model USB-5681
    Description National Instruments USB-5681 RF Power Sensor Device
    Frequency Range 10 MHz to 18 GHz
    Input Signal Strength -40 dBm to +20 dBm
    Measurement Ranges +20 dBm to -7 dBm, -7 dBm to -40 dBm
    Bandwidth Support 50 kHz
    Measurement Speed 100 S/s
    Typical Uncertainty <3 %
    Safety Standards IEC 61010-1, EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1
    Input Voltage and Current 5 VDC, 450 mA
    Maximum Voltage at RF Port ±20 VDC
    Absolute Maximum Power +30 dBm

    Question 1: What is the frequency range of the USB-5681?
    Answer 1: 10 MHz to 18 GHz

    Question 2: What input signal strength can the USB-5681 measure?
    Answer 2: -40 dBm to +20 dBm

    Question 3: What is the measurement speed of the USB-5681?
    Answer 3: 100 samples per second

    Question 4: What power does the USB-5681 operate on?
    Answer 4: 5 VDC, 450 mA

    Question 5: What is the USB-5681’s typical uncertainty?
    Answer 5: <3%