200176A-01

This device, with part numbers 783130-01, 154888C-02L, offers 7½-digit resolution, a voltage range of ±100 mV to ±1000 V, and a current range of ±1 µA to ±3 A.

In Stock | Ships Today

img

    Description

    This product is identified by part numbers 783130-01 and 154888C-02L. It boasts a high-resolution measurement capability of 7½-Digit, ensuring precise readings across various applications. The device operates within a voltage range of ±100 mV to ±1000 V, which can be DC or AC coupled, catering to a wide array of electrical testing requirements.

    In terms of current measurement, it has a broad range from ±1 µA to ±3 A, accommodating low to high current scenarios. Its sample rate in digitizer mode is exceptionally versatile, ranging from 10 S/s to 1.8 MS/s, allowing for flexible data acquisition speeds suited to varying requirements. The input impedance is rated at 10 MΩ ± 2% in parallel with 90 pF, ensuring accurate measurements by minimizing loading effects on the circuit under test.

    The device can safely handle a maximum DC voltage component of 400 V, and it is capable of operating across a frequency range of 15 Hz to 500 KHz. Its period measurement range extends from 2 µs to 66.67 ms, allowing for detailed analysis of periodic signals. ADC linearity is exceptionally high, up to 0.5 ppm of reading + 0.5 ppm, ensuring accuracy in converted digital signals.

    Before first use, a warm-up time of 60 minutes is required to achieve accurate measurements. To maintain its precision, a calibration period is recommended once every 2 years. The device is designed with robust input protection, capable of withstanding up to 1000 VDC or Vpk, and its current mode includes a fuse rating of T 3.5 A 1000 V, time-lag with a minimum interrupt rating of 10 kA S, ensuring safety and reliability during operation.

    Specification Detail
    Part Numbers 783130-01, 154888C-02L
    Resolution 7½-Digit
    Voltage Range ±100 mV to ±1000 V (DC or AC coupled)
    Current Range ±1 µA to ±3 A
    Sample Rate (Digitizer Mode) 10 S/s to 1.8 MS/s
    Input Impedance 10 MΩ ± 2% in parallel with 90 pF
    Maximum DC Voltage Component 400 V
    Frequency Range 15 Hz to 500 KHz
    Period Measurement Range 2 µs to 66.67 ms
    ADC Linearity Up to 0.5 ppm of reading + 0.5 ppm
    Warm-up Time 60 minutes
    Calibration Period Once every 2 years
    Input Protection 1000 VDC or Vpk
    Current Mode Fuse Rating T 3.5 A 1000 V, time-lag Minimum interrupt rating: 10 kA S

    Question 1: What is the resolution of the PXIe-4081?
    Answer 1: 7½-Digit

    Question 2: What voltage range does the PXIe-4081 support?
    Answer 2: ±100 mV to ±1000 V

    Question 3: What is the current measurement range of the PXIe-4081?
    Answer 3: ±1 µA to ±3 A

    Question 4: How long is the recommended calibration period for the PXIe-4081?
    Answer 4: Every 2 years

    Question 5: What is the warm-up time required for the PXIe-4081?
    Answer 5: 60 minutes