Description
The product features part numbers 784181-01 and 785114-01, designed to cater to a wide array of applications requiring precise signal generation and analysis. It operates at a maximum frequency of 20 MHz, ensuring high performance in various testing scenarios.
Its step response rise time is significantly efficient at 14.8 ns, offering rapid response to changes in signal. This attribute is critical for applications requiring quick adjustments and high precision.
The device supports an arbitrary waveform size ranging from 2 to 64,000,000 samples, providing immense flexibility in waveform generation. This vast range allows users to create detailed and complex waveforms for testing and simulation purposes.
With digital filter enabled, the user sample rate can be adjusted from 5.6 µS/s to 200 MS/s, and with the digital filter disabled, it ranges from 3.125 MS/s to 200 MS/s. This flexibility ensures that users can optimize the device performance based on the specific requirements of their applications.
The frequency step size is as precise as 2.84 µHz, allowing for extremely fine adjustments to the output frequency. This level of control is paramount for tasks requiring the highest degrees of accuracy.
It is capable of handling up to 8,192 waveform points, enabling the generation of highly complex signals. The reference clock frequency operates at 100 MHz (<±25 ppm), providing a stable timing source for waveform generation and analysis.
The sample clock rate is impressively high at 800 MHz, facilitating the processing of signals with great speed and efficiency. For interfacing, the PFI I/O frequency range spans from 0 MHz to 25 MHz, accommodating a broad spectrum of external devices and signals.
It is designed to withstand a maximum input voltage of +5 V, safeguarding
| Specification | Details |
|---|---|
| Part Numbers | 784181-01, 785114-01 |
| Maximum Frequency | 20 MHz |
| Step Response Rise Time | 14.8 ns |
| Arbitrary Waveform Size | 2 to 64,000,000 samples |
| User Sample Rate (Digital Filter Enabled) | 5.6 µS/s to 200 MS/s |
| User Sample Rate (Digital Filter Disabled) | 3.125 MS/s to 200 MS/s |
| Frequency Step Size | 2.84 µHz |
| Waveform Points | 8,192 |
| Reference Clock Frequency | 100 MHz (<±25 ppm) |
| Sample Clock Rate | 800 MHz |
| PFI I/O Frequency Range | 0 MHz to 25 MHz |
| Maximum Input Voltage | +5 V |
| Operating Shock | 30 g peak, half-sine, 11 ms pulse |
| Random Vibration (Operating) | 5 Hz to 500 Hz, 0.3 grms |
| Random Vibration (Non-operating
Question 1: What is the max frequency of the PXIe-5413? Question 2: How many waveform samples does PXIe-5413 support? Question 3: What is the max input voltage of the PXIe-5413? Question 4: What is the step response rise time of the PXIe-5413? Question 5: What is the user sample rate with digital filter off? |