img

539839A-27

The cDAQ-9185 CompactDAQ Chassis, with part numbers 785064-01, 786473-01, 787929-01, offers 50 ppm timing accuracy and supports LabVIEW programming.

In Stock | Ships Today

img

    Description

    The cDAQ-9185 model falls under the category of CompactDAQ Chassis, showcasing a versatile and robust platform for measurement and automation needs. This device is identified by part numbers 785064-01, 786473-01, and 787929-01, catering to a variety of configurations and applications.

    One of the key specifications of the cDAQ-9185 is its timing accuracy, which is maintained at 50 ppm of the sample rate. This precision ensures reliable and consistent data acquisition, critical for sensitive measurements and control systems. The chassis supports programming through LabVIEW and LabWindows/CVI, offering flexibility and ease of use for developers and engineers.

    Despite its compact dimensions of 7.01 x 3.47 x 2.52 inches, the cDAQ-9185 is designed to withstand harsh environments. It weighs 23.3 oz and operates efficiently across a wide temperature range from -40 °C to 70 °C. Additionally, it is capable of being stored in temperatures ranging from -40 °C to 85 °C.

    The device’s durability is further underscored by its capability to operate and be stored in humidity ranges of 10% to 90% RH and 5% to 95% RH, respectively, without condensing. It is also engineered to handle operating vibrations of 5 grms (random) and 5 g (sinusoidal) in the frequency range of 10 to 500 Hz, ensuring reliable performance in mechanically demanding situations.

    Furthermore, the CompactDAQ Chassis cDAQ-9185 provides an option for calibration, which is available with NIST accreditation through a 3rd party. This feature adds an extra layer of reliability and precision, ensuring that the device meets stringent accuracy standards for professional and industrial applications.

    Specification Detail
    Part Numbers 785064-01, 786473-01, 787929-01
    Model cDAQ-9185
    Category CompactDAQ Chassis
    Timing Accuracy 50 ppm of sample rate
    Programming Interface LabVIEW, LabWindows/CVI
    Weight 23.3 oz
    Dimensions (W x H x D) 7.01 x 3.47 x 2.52 in
    Operating Temperature Range -40 °C to 70 °C
    Storage Temperature Range -40 °C to 85 °C
    Operating and Storage Humidity Range 10% to 90% RH (operating), 5% to 95% RH (storage), non-condensing
    Operating Vibrations 5 grms (random), 5 g (sinusoidal), 10 to 500 Hz
    Calibration Availability Yes, with NIST accreditation through 3rd party

    Question 1: What is the timing accuracy of cDAQ-9185?
    Answer 1: 50 ppm of the sample rate.

    Question 2: Which programs support cDAQ-9185 programming?
    Answer 2: LabVIEW and LabWindows/CVI.

    Question 3: What are the operating temperature limits of cDAQ-9185?
    Answer 3: -40 °C to 70 °C.

    Question 4: Can the cDAQ-9185 withstand high humidity?
    Answer 4: Yes, 10% to 90% RH non-condensing.

    Question 5: Is calibration available for cDAQ-9185?
    Answer 5: Yes, with NIST accreditation via 3rd party.