Description
Item #: 54600B
Manufacturer: Agilent
Series: 54600
54600B by Agilent is an Oscilloscope in the 54600 series. 54600B features 2 Channels and a Bandwidth of 100 MHz.
The HP Agilent 54600B Oscilloscope has two input channels, a bandwidth of 100 MHz, a maximum of 1.5 million points per second screen update rate, and sweep speeds from 5 s/div to 2 ns/div. The 54600B Oscilloscope is suitable for field service and education, benchtop troubleshooting, production test applications, and other applications where the user desires a stable, reliable oscilloscope at an affordable cost.
The improved display on the 54600B Oscilloscope provides the user with waveform slew rate data, similar to analog oscilloscope displays. Furthermore, the 54600B has brighter traces representing waveforms which are gradually being altered and dimmer traces representing waveforms that are being altered swiftly. Another feature of this model is pretrigger viewing, which allows the user to look at incidents that they would not be able to spot with an analog oscilloscope. Pretrigger viewing permits the user to view what happened prior to the trigger incident, so they can troubleshoot more competently. The 54600B Oscilloscope also has an autoscale feature. Autoscale takes away the predicament of having to reset the scope each time the user moves the probe from one test point to another. Instead, the user has to press the autoscale button and the time, voltage, and trigger limits will be set automatically.
With the 54600B Oscilloscope, automatic measurements of frequency, time, and voltage can be completed, along with user-defined cursor measurements. These features ensure that waveform characterization is a swift and simple process. Additionally, the peak detect function allows the user to discover narrow glitches.
Specifications
Manufacturer | Agilent |
---|---|
Part Number | 54600B |
Series | 54600 |
Type | Oscilloscope |
Channels | 2 |
Bandwidth | 100 MHz |
Rise Time | <3.5 ns |
Input Impedance | 1 MΩ, ~ 18 pF |
Maximum Input | 400 V |
Maximum Sample Rate | 20 MSa/s |
Option 1 | RS-03 Magnetic interface shielding added to CR |
Option 2 | RE-02 Display shield added to CRT to reduce radiated interface |
Option 90 | Delete probes |
Option 103 | Operator training kit (comes with training signal board and lab workbook) |
Option 104 | Carrying case (protects scope for shipping or baggage checking) |
Option 106 | HP BenchLink Scope software for Windows |
Option 1CM | Rack Mount Kit |
Option ABA | English user manual |
Option ABD | German user manual |
Option ABE | Spanish user manual |
Option ABF | French user manual |
Option ABZ | Italian user manual |
Option ABO | Tawian Chinese user manal |
Option ABJ | Japanese user manual |
Option AB1 | Korean user manual |