Description
The GPIB-120A Bus Expander/Isolator, carrying the part number 776564-06, falls under the GPIB category. This model, specifically designed for use in the U.K. with a 240 VAC power supply, is an essential tool for expanding the capabilities of GPIB system devices. Its primary function is to expand the GPIB system devices limit from 15 to 28, while also providing an electrically isolated interface for enhanced safety and performance.
Adhering to the IEEE 488.1 communication standard, the GPIB-120A ensures compatibility and ease of integration into existing systems. It features a transparent software compatibility, eliminating the need for rewriting user’s application software, thereby simplifying the deployment process. Furthermore, this device is capable of doubling the cable length limit from the standard 20 meters, enabling more flexible system configurations.
When it comes to safety, the GPIB-120A offers operating and breakdown isolations rated at 60 V and 1600 V respectively, ensuring the device operates safely even in demanding environments. The device supports various connector types, including Amphenol or Cinch series 57 Microribbon or Amp Champ type, providing versatility in connection options. Additionally, the front panel features 7 LEDs to indicate Active Controller and System Controller states, simplifying monitoring and diagnostics.
The GPIB-120A is engineered to handle 16 signal lines, which include 5 interface management lines, 3 handshake lines, and 8 data lines, ensuring comprehensive control and data transfer capabilities. Despite its extensive functionalities, the device has a typical power requirement of only 27 VA, making it an energy-efficient choice. Lastly, it is designed to minimize data transfer rate degradation, maintaining a low 250 ns per byte, thereby ensuring high performance and reliability in data-intensive applications.
| Specification | Detail |
|---|---|
| Part Number | 776564-06 |
| Category | GPIB |
| Model | GPIB-120A |
| Description | GPIB-120A Bus Expander/Isolator, U.K. 240 VAC |
| Function | Expands GPIB system devices limit from 15 to 28, Electrically isolated interface |
| Communication Standard | IEEE 488.1 |
| Software Compatibility | Transparent software; no need for rewriting user’s application software |
| Cable Length Extension | Doubles the cable limit of 20 meters |
| Operating and Breakdown Isolations | 60 V and 1600 V respectively |
| Connector Type | Amphenol or Cinch series 57 Microribbon or Amp Champ type |
| Front Panel LEDs | 7 LEDs indicating Active Controller and System Controller states |
| Signal Lines | 16 signal lines (5 interface management lines, 3 handshake lines, 8 data lines) |
| Power Requirement | Typical 27 VA |
| Data Transfer Rate Degradation | 250 ns per byte |