Description
The SCXI-1104C model falls under the SCXI & Legacy category, showcasing its significance in the realm of legacy systems and specialized interfaces. Its part numbers, 776572-04C and 183087H-05, indicate its unique identification for procurement and support documentation.
This model is described as a 32 ch, 42 V Multiplexer, highlighting its capability to handle multiple signal inputs with a considerable voltage threshold. It supports 32 differential channels, providing ample connectivity for various sensors and input devices. The inclusion of a 10 kHz cut-off frequency filter further enhances its utility by allowing for precise signal processing and noise reduction in measurement applications.
For integration into multichassis systems, the SCXI-1346 adapter is required, ensuring compatibility and expandability with other system components. Analog ground pin options include Pins 1,2, 4, or 19, offering flexibility in grounding configurations to suit different application needs. Despite lacking overvoltage protection, this model does feature short-circuit protection, ensuring system safety and reliability during unforeseen electrical faults.
Optimal performance is achieved after a recommended warm-up time of 20 minutes, with operations supported across a temperature range from 0 to 50 °C. Maintenance and accuracy are upheld through annual calibration, or as needed, ensuring long-term reliability and precision in measurements.
Compatibility with NI-DAQ version 6.5.1 or higher software drivers indicates ease of integration with modern data acquisition systems, while connectivity is facilitated through a 50-pin male ribbon cable (back) and a 96-pin male DIN C (front), offering robust and versatile physical interface options. The obsolete status of this model emphasizes its position within legacy systems, necessitating careful consideration for new applications or replacement strategies.
| Specification | Detail |
|---|---|
| Part Number | 776572-04C, 183087H-05 |
| Category | SCXI & Legacy |
| Model | SCXI-1104C |
| Description | 32 ch, 42 V Multiplexer |
| Channels | 32 differential |
| Cut-off Frequency Filter | 10 kHz |
| Required Adapter for Multichassis System | SCXI-1346 |
| Analog Ground Pin Options | Pins 1,2, 4, or 19 |
| Overvoltage Protection | No |
| Short-circuit Protection | Yes |
| Recommended Warm-up Time | 20 minutes |
| Operating Temperature | 0 to 50 °C |
| Calibration Frequency | Annually or as needed |
| Software Driver | NI-DAQ version 6.5.1 or higher |
| Connectors | 50-pin male ribbon cable (back), 96-pin male DIN C (front) |
| Obsolete Status
Question 1: What is the cut-off frequency of the SCXI-1104C? Question 2: How many channels does the SCXI-1104C support? Question 3: What is the SCXI-1104C’s recommended warm-up time? Question 4: Does the SCXI-1104C require an adapter for multichassis systems? Question 5: Is the SCXI-1104C compatible with NI-DAQ version 6.5.1 or higher? |