Description
The Compact FieldPoint series introduces the cFP-TC-120, a high-precision 16-Bit Thermocouple Input Module (TC, mV) designed for versatile thermocouple types. The model number for this advanced module is 777318-120, ensuring you get the right component for your sophisticated measurement needs.
This module boasts an 8-Channel Thermocouple Input, allowing for multiple temperature measurements simultaneously. It supports a wide range of thermocouples, including types B, E, R, K, J, N, T, S, making it highly versatile for various industrial applications. The device is engineered to withstand 2,300 Vrms overvoltage protection, ensuring durability and reliability in harsh environments.
Designed to operate in extreme conditions, the cFP-TC-120 functions within a temperature range of -40 to 70°C and can be stored in temperatures ranging from -55 to 85°C. Its 16-bit resolution guarantees precise temperature measurements, and the integrated 50/60 Hz noise filter enhances the signal quality for accurate readings.
With a lightweight design, weighing only 3.7 oz, and compact dimensions of 5.0 x 3.5 x 1.0 in, this module is easy to install and integrate into existing systems. It supports a variety of input voltage ranges, including ±25, ±50, ±100, and -20 to 80 mV, and offers extensive temperature reading ranges from -454 to 3,218°F, accommodating a broad spectrum of industrial temperature monitoring tasks.
| Specification | Detail |
|---|---|
| Part Number | 777318-120 |
| Category | Compact FieldPoint |
| Model | cFP-TC-120 |
| Description | 16-Bit Thermocouple Input Module (TC, mV) |
| Channels | 8-Channel Thermocouple Input |
| Supported Thermocouples | B, E, R, K, J, N, T, S |
| Overvoltage Protection | 2,300 Vrms |
| Operating Temperature Range | -40 to 70°C |
| Storage Temperature Range | -55 to 85°C |
| Resolution | 16-bits |
| Noise Filter | Integrated 50/60 Hz |
| Weight | 3.7 oz |
| Dimensions | 5.0 x 3.5 x 1.0 in |
| Input Voltage Ranges | ±25, ±50, ±100, and -20 to 80 mV |
| Temperature Reading Ranges | -454 to 3,218°F, 0 to 2,
Question 1: What is the model number of the TC input module? Question 2: How many channels does the cFP-TC-120 have? Question 3: What thermocouple types does the cFP-TC-120 support? Question 4: What is the overvoltage protection of the cFP-TC-120? Question 5: What is the operating temperature range of the cFP-TC-120? |