img

777640-03

The AT-MIO-16DE-10, a legacy DAQ device with part numbers 777640-01, 184578P-01, features a 100 kS/s sampling rate and 12-bit resolution.

In Stock | Ships Today

img

    Description

    The AT-MIO-16DE-10 is a legacy DAQ device that falls under the E Series, specifically the NI-6021E family. It is designed to connect via the ISA bus, catering to systems that support this interface. The device is identified by part numbers 777640-01 and 184578P-01, ensuring compatibility and ease of replacement or integration into existing setups.

    This device boasts a maximum sampling rate of 100 kS/s with a resolution of 12 bits, providing precise and accurate data acquisition capabilities. It offers flexibility in its analog input channels, supporting either 16 single-ended or 8 differential configurations. Additionally, it is equipped with 2 analog output channels and 32 digital I/O lines with TTL compatibility, enhancing its utility in various data acquisition and control applications.

    The AT-MIO-16DE-10 operates with a source voltage of 5V and includes two 24-bits, 20 MHz timers for precise timing and control tasks. Its input/output voltage range is quite versatile, ranging from ±0.05 to ±10 V and ±10 V, accommodating a wide range of signals. This device is also NIST-calibrated, ensuring accuracy and reliability in measurements.

    One of the standout features of this DAQ device is its compatibility with over 70 signal conditioning accessories, significantly expanding its application possibilities. It supports various operating systems, including Windows 2000, NT, and Me, making it suitable for use with older computer systems. Furthermore, it is compatible with several software platforms such as LabVIEW, Measurement Studio, and VI Logger, offering versatility in data analysis and system integration.

    Despite its obsolete status, the AT-MIO-16DE-10 is still available from Apex Waves, providing an opportunity for those in need of legacy DAQ devices to acquire this high-quality equipment. Its extensive features and compatibility make it an excellent choice for a wide range of data acquisition and control tasks.

    Specification Detail
    Part Numbers 777640-01, 184578P-01
    Category Legacy DAQ Devices
    Model AT-MIO-16DE-10
    Family E Series, NI-6021E
    Connection ISA bus
    Maximum Sampling Rate 100 kS/s
    Resolution 12 bits
    Analog Input Channels 16 single-ended or 8 differential
    Analog Output Channels 2
    Digital I/O Lines 32 with TTL
    Source Voltage 5V
    Timers Two 24-bits, 20 MHz
    Input/Output Voltage Range ±0.05 to ±10 V and ±10 V
    Calibration NIST-calibrated
    Signal Conditioning Accessories More than 70
    Operating Systems Windows 2000/NT/Me
    Software Compatibility LabVIEW, Measurement Studio, VI Logger
    Obsolete Status Announced but available from Apex Waves

    Question 1: What is the max sampling rate of the AT-MIO-16DE-10?
    Answer 1: 100 kS/s

    Question 2: How many analog output channels does it have?
    Answer 2: 2 analog output channels

    Question 3: Can the AT-MIO-16DE-10 connect via the ISA bus?
    Answer 3: Yes, it connects via the ISA bus.

    Question 4: What operating systems does it support?
    Answer 4: Windows 2000, NT, Me

    Question 5: Is the AT-MIO-16DE-10 NIST-calibrated?