The product features a variety of Part Numbers, including 777650-01, 777650-04, 777650-06, 777650-07, and 185182B-01, to cater to diverse application requirements. It is equipped with 2 analog input channels, ensuring versatile data acquisition capabilities.
It boasts an Analog Input Bandwidth of up to 15 MHz, facilitating the capture of high-frequency signals. The Input Voltage Range is quite flexible, ranging from ±50 mV to ±5 Volts, and can be extended up to ±50 Volts with attenuation, allowing for the measurement of both low and high voltage signals efficiently.
The device supports a variable Sampling Rate from 20 MS/s down to 1 kS/s, making it suitable for a wide range of signal types. Additionally, it offers an Effective Sampling Rate (with RIS) of 1 GS/s, significantly enhancing its capability to analyze fast transient events with high precision.
With an On-board Acquisition Memory of 663,000 samples, it provides ample space for data storage, ensuring that users do not miss out on crucial signal data during analysis. The Input Connectors include 2 BNC female for analog signals and 1 BNC female for TRIG, offering convenient and reliable connections.
The product is designed with a DC Accuracy of ±2.5% full scale at all gains, ensuring accurate measurements. Input Coupling is software-selectable, which provides flexibility in signal acquisition modes. Additionally, it features an Input Protection of ±42 Volts, safeguarding the device against potential damage from high voltage inputs.
The Triggering System Input Range is ±5 Volts, and the Triggering System Input Impedance is 1 MΩ, facilitating efficient and flexible triggering capabilities for various signal types.
| Specification | Detail |
|---|---|
| Part Numbers | 777650-01, 777650-04, 777650-06, 777650-07, 185182B-01 |
| Channels | 2 analog input channels |
| Analog Input Bandwidth | 15 MHz |
| Input Voltage Range | ±50 mV to ±5 Volts (up to ±50 Volts with attenuation) |
| Sampling Rate | 20 MS/s down to 1 kS/s |
| Effective Sampling Rate (with RIS) | 1 GS/s |
| On-board Acquisition Memory | 663,000 samples |
| Input Connectors | 2 BNC female (analog), 1 BNC female (TRIG) |
| DC Accuracy | ±2.5% full scale at all gains |
| Input Coupling | Software-selectable |
| Input Protection | ±42 Volts |
| Triggering System Input Range | ±5 Volts |
| Triggering System Input Impedance | 1 MΩ |
Question 1: What is the Analog Input Bandwidth of USB-5102?
Answer 1: 15 MHz
Question 2: What is the Input Voltage Range of USB-5102?
Answer 2: ±50 mV to ±5 Volts, extensible to ±50 Volts
Question 3: What is the Sampling Rate range of USB-5102?
Answer 3: 20 MS/s down to 1 kS/s
Question 4: How many analog input channels does USB-5102 have?
Answer 4: 2 channels
Question 5: What is the effective sampling rate with RIS for USB-5102?
Answer 5: 1 GS/s