img

777687-14T

The NI SCXI-1314T is a TEDS Bridge Sensor Terminal Block with RJ50 connectors, compatible with SCXI-1520, and operates within 0 to 50 °C.

In Stock | Ships Today

img

    Description

    The product with the Part Number 777687-14 belongs to the Category of SCXI & Legacy. Specifically, it is the Model SCXI-1314, which is known as the NI SCXI-1314T, TEDS Bridge Sensor Terminal Block (RJ50 Connectors). This particular model is designed to be Compatible with the SCXI-1520 module.

    It features 88 Screw Terminals, which are configured in eight groups with 11 terminals per group. Additionally, it includes Two precision 100 kΩ Shunt Calibration Resistors and a Quarter-Bridge Completion Resistor that is a precision, factory default 350 Ω. These specifications ensure precise measurements and compatibility with various sensors and devices.

    The Operating Temperature Range for this terminal block is from 0 to 50 °C, while the Storage Temperature Range extends from –20 to 70 °C. It can operate within a Relative Humidity Range of 10 to 90% (non-condensing), ensuring reliability in various environmental conditions.

    This product adheres to several Safety Standards, including IEC 61010-1, EN 61010-1, UL 61010-1, and CAN/CSA C22.2 No. 61010-1. Despite its Obsolete Status, as announced by National Instruments, it remains available from Apex Waves, allowing users to acquire this specific model for their legacy systems or specific needs. Additionally, Calibration services are available, ensuring that the device meets all necessary precision and performance standards.

    Specification Detail
    Part Number 777687-14
    Category SCXI & Legacy
    Model SCXI-1314
    Description NI SCXI-1314T, TEDS Bridge Sensor Terminal Block (RJ50 Connectors)
    Compatible Module SCXI-1520
    Screw Terminals 88 (Configured in eight groups, 11 per group)
    Shunt Calibration Resistors Two precision 100 kΩ
    Quarter-Bridge Completion Resistor Precision, factory default 350 Ω
    Operating Temperature Range 0 to 50 °C
    Storage Temperature Range –20 to 70 °C
    Relative Humidity Range 10 to 90% (non-condensing)
    Safety Standards IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA C22.2 No. 61010-1
    Obsolete Status Announced by National Instruments, available from Apex Waves
    Calibration Available, N

    Question 1: What is the Part Number of the TEDS Bridge Sensor Terminal Block?
    Answer 1: 777687-14

    Question 2: How many Screw Terminals does the SCXI-1314T have?
    Answer 2: 88 Screw Terminals

    Question 3: What is the Operating Temperature Range of SCXI-1314T?
    Answer 3: 0 to 50 °C

    Question 4: Is calibration service available for SCXI-1314T?
    Answer 4: Yes, calibration services are available.

    Question 5: Can SCXI-1314T be used with SCXI-1520?
    Answer 5: Yes, it’s compatible with SCXI-1520.