The NI PXI-2512 is a 7-channel, 10A FIU switch module with a maximum switching voltage of 50 VDC and includes a DB8F-40A cable.

In Stock | Ships Today

img

    Description

    The NI PXI-2512 is a high-performance, 7-Channel 10A Fault Insertion Unit (FIU) Switch Module, designated with the part number 778572-12. This module falls under the category of PXI Switches and is designed to facilitate robust and precise testing capabilities in automated test equipment environments.

    The PXI-2512 is capable of handling a maximum switching current of 10 A, with the ability to endure pulse currents up to 50 A for durations as brief as 600 μs. This module operates safely within a maximum switching voltage range of 50 VDC and 30 V ACrms, ensuring versatility in testing various electrical components and systems.

    An important safety feature of the PXI-2512 is its overcurrent detection, which is typically set to 10.5 A. This function, coupled with a 20 ms delay in overcurrent detection, protects the module and connected devices from potential damage due to current overloads.

    Connectivity is facilitated through two DSUB, 8 position male front panel connectors. The module also includes one DB8F-40A Cable for 8-pin DSUB and one DB8F-40A Cable for bare wire connections, ensuring easy and reliable connections to the test setup.

    Despite its powerful capabilities, the PXI-2512 maintains an efficient power consumption profile, requiring just 1.0 Watts at 3.3 V and 13.0 W at 5 Volts. Its physical dimensions accommodate a 3U, two-slot PXI module footprint, making it a compact yet powerful addition to any PXI-based test system.

    Question 1: What is the max switching current of the PXI-2512?
    Answer 1: 10 A

    Question 2: How long can the PXI-2512 handle 50 A pulse currents?
    Answer 2: Up to 600 μs

    Question 3: What is the maximum switching voltage of the PXI-2512?
    Answer 3: 50 VDC

    Question 4: What safety feature does the PXI-2512 have?
    Answer 4: Overcurrent detection set at 10.5 A

    Question 5: What connectors come with the PXI-2512?
    Answer 5: Two DSUB, 8 position male and DB8F-40A cables

    Specification Detail
    Part Number 778572-12
    Category PXI Switches
    Model PXI-2512
    Description NI PXI-2512 7-Channel 10A FIU Switch Module
    Channels 7-Channel
    Maximum Switching Current 10 A
    Maximum Pulse Current 50 A (for 600 μs max)
    Maximum Switching Voltage 50 VDC, 30 V ACrms
    Overcurrent Detection Limit 10.5 A typical
    Overcurrent Detection Delay 20 ms
    Front Panel Connectors Two DSUB, 8 position male
    Cable Included One DB8F-40A Cable (for 8-pin DSUB) and one DB8F-40A Cable (to the bare wire)
    Power Consumption 1.0 Watts at 3.3 V, 13.0 W at 5 Volts
    Physical Size 3U, two slot, PXI module